CityPleat

  • 2 i 1 lösning
  • Partikel och molekylärfiltrering
  • Hög prestanda med hjälp av RAD (Rapid Adsorption Dynamics)
  • Brännbar
  • Enkel uppgradering till partikel och molekylärfiltrering
  • Finns med plastram som alternativ
  • ICON6
  • ICON7 iso16890.ai
  • ICON26 ozone 5
  • ICON27 ozone 6
  • ICON37 ISO10121
Modellnamn ISO -klassificering ISO 16890 Filterklass enligt EN779 Bredd (mm) Höjd (mm) Djup (mm) Luftflöde (m3/h) Initialt tryckfall (Pa)
CityPleat-100-289x594x44 Coarse 65% G4 289 594 44 900 135
CityPleat-200-594x594x44 Coarse 65% G4 594 594 44 3175 135
CityPleat-200-289x594x44 Coarse 65% G4 289 594 44 1500 135
CityPleat-200-594x594x95 Coarse 65% G4 594 594 95 3185 90
CityPleat-200-289x594x95 Coarse 65% G4 289 594 95 1500 90
CityPleat-480-289x594x95 Coarse 65% G4 289 594 95 1500 50
CityPleat-100-594x594x44 Coarse 65% G4 594 594 44 1900 135
CityPleat-480-594x594x95 Coarse 65% G4 594 594 95 3185 50

Specifikationer

Applikation
Kombinerad förfiltrering av gasföroreningar i stadsmiljö som t.ex. köpcenter och andra offentliga byggnader
Ram
Fuktbeständig papp
Media
Syntet/aktivt kol
Relativ fuktighet
30% - 70%
Standarddimension
Frontdimension enligt EN 15805
installationsalternativ
Förfilter i filterskåp CamCube HF och CamCube AC
Max luftflöde
1,25 x nominellt flöde

Hospitals & Healthcare: St. James Hospital Dublin

Case Study: St James Hospital Prevents Aspergillus. Healthcare facilities must maintain the highest levels of cleanliness to promote health and healing. Camfil provides air cleaners for these environments. St. James Hospitaal in Dublin used Camfil for Aspergillus prevention.

Case Studies

Food & Beverage: World's Leading Beverage Company

Case Study: Clean Air For Leading Beverage Manufacturer. Air is the only ingredient involved in every aspect of food and beverage manufacturing. Air comes into contact with products from storage of goods all way to packaging. How can we help to keep your food processes safe?

Case Studies

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies

UNIVERSITY SEES PROOF OF 24% LOWER ANNUAL ENERGY COSTS USING CAMFIL FILTER VS COMPETING FILTER

Case Study: Energy Savings At Western United States University. A Life Cycle Costing (LCC) analysis proved the Camfil Durafil filter operated at a 24% lower energy cost per year than the Viledon T-60. The Camfil product would save the customer $14 per filter per year versus the alternative.

Case Studies