ActiCarb Basic Gas

  • High efficiency filter for safety and protection uses
  • Individual test of the leak rate
  • Individual certificate
  • Proven product, the factory controlled characteristics of which are maintained after handling and transportation
  • Parameters integrated into internal software for customer simulation
  • ICON6
Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
610 610 292 1200* 200
610 610 292 1200* 200
305 610 292 600* 200
305 610 292 600* 200

Specifications

Application
Animal or research laboratories to capture amoniac
Frame
Stainless steel, Steel, painted
Gasket
½ round 15 mm moulded neoprene foam
Comment
Media: 50 mm (2 inch) bed depth of chromium-free impregnated activated carbon; vibrated and tamped to meet leakage requirements Adsorbent: H3P04 (10%)
Gases to trap: Basic gases (NH2, OH..)
Impregnation: Acid
Particle size: 2 mm extruded
Relative Humidity: < 90%
Temperature: 80°C maximum in continues
Adsorbent volume (liters): full size 65 liters +/- 37 kg - half size 32,5 liters +/- 16 kg
Controls: Individual test run for leakages (< 2,5 x 10-4) and pressure drop