CamGT 3V-600

  • Alhainen painehäviö kosteissakin olosuhteissa
  • Erinomaisen kestävä
  • Vedenkestävä
  • Kestää suolaa
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5 Low Pressure Drop
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
Tuotetyyppi ISO 16890 Suodatusluokka EN779 Suodatusluokka EN1822 Leveys (mm) Korkeus (mm) Syvyys (mm) Ilmavirta (m³/h) Alkupainehäviö (Pa)
CAM GT 3V 600-F9-Std ePM1 85% F9 592 592 600 4250 115
CAM GT 3V 600-F8-Std ePM1 80% F8 592 592 600 4250 100
CAM GT 3V 600-E10-Std E10 592 592 600 4250 135
CAM GT 3V 600-E11-Std E11 592 592 600 4250 140
CAM GT 3V 600-E12-Std E12 592 592 600 4250 190
E12 592 592 600 4250 190
CAM GT 3V 600-E13-Std H13 592 592 600 4250 240
  Tuotteelle on saatavilla on painehäviön laskentatyökalu

Laske painehäviö

m3/h
= Pa
Liian suuri ilmamäärä tälle suodattimelle

Tekniset tiedot

Käyttösovellus
Kaasuturbiinien tuloilmasuodatukseen
Kehysmateriaali
Valettu muovikehys
Suodatinmateriaali
Lasikuitu
Max lämpötila (°C)
70°C
Suhteellinen ilmankosteus
100%
Suositeltu loppupainehäviö
600 Pa
Erotinmateriaali
Kuumaliima
Tiiviste
Saumaton polyuretaani
Suojaverkko puhtaalla puolella
Tukiverkko suodatinmateriaalille
Tiiviste
Polyuretaani
Max ilmavirta
1,8 x nimellisilmamäärä

Samankaltaiset tuotteet

Artikkelit, jotka liittyvät tuotteeseen CamGT

LNG & Air Filtration

Case Study: Achieving high reliability and availability compression systems for LNG export sites.

Case Studies

Camfil designs a compact SOLUTION on existing platform

Case Study: The units are exposed to harsh environmental conditions that lead to spikes in pressure drop (dP) and excessive engine degradation from fouling and corrosion. As a result, the customer was forced to schedule unwanted shutdowns for maintenance.

Case Studies

CamGT Filters Reduce Noise & Bring Additional Profits Due To Lower Pressure Drop

Case Study: Noise complaints from neighboring communities prompted the plants to evaluate a noise-reducing filtration system.

Case Studies

Dalkia Upgrades To EPA Class

Case Study: Camfil Wins Dalkia Over Four Competitors. Dalkia designed 12 testing benches to compare four air filtration combinations on three sites in France with different operating environments. Four competitors were free to select their best combinations.

Case Studies

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies Turbiinit ja turbokompressorit

Camfil Oy
Ruukinmestarintie 11
02330 ESPOO
info.finland(at)camfil.com
etsi yhteyshenkilö