Hi-Flo A, UF

The entry level range of glass fiber bag filters with a reduced amount of bags with steel frame. Thanks to the conical and tapered bag design, these filters come with the optimum balance between price and total cost of ownership. Available in all efficiencies according to ISO16890.

  • Low initial pressure drop
  • Flat pressure drop curve
  • Comprehensive range of standard sizes
  • Innovative pocket design for optimum air distribution
  • Conical pockets
  • Robust metal header frame
  • ICON3 efficiency guarantee
  • ICON7 iso16890.ai
  • ICON23 Eurovent_no_abc
  • ICON31 Mount_bagfilters
Item Type ISO 16890 Filter Class EN779 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa) Energy (kWh/year) Energy Class (Eurovent)
A5 ePM10 60% M5 592 592 600 3400 45 748 C
B5 ePM10 60% M5 490 592 600 2800 45 C
C5 ePM10 60% M5 287 592 600 1700 45 C
C5-33 ePM10 60% M5 287 287 600 800 45 C
A5-63 ePM10 60% M5 592 287 600 1700 45 C
A5-65 ePM10 60% M5 592 490 600 2800 45 C
AL5 ePM10 60% M5 592 892 600 5000 45 C
BL5 ePM10 60% M5 490 892 600 4100 45 C
CL5 ePM10 60% M5 287 892 600 2500 45 C
UF5 ePM10 60% M5 592 592 600 3400 40 544 A
UG5 ePM10 60% M5 490 592 600 2800 40 A
UH5 ePM10 60% M5 287 592 600 1700 40 A
UH5-33 ePM10 60% M5 287 287 600 800 40 A
UF5-63 ePM10 60% M5 592 287 600 1700 40 A
UF5-65 ePM10 60% M5 592 490 600 2800 40 A
A5/520 ePM10 60% M5 592 592 520 3400 50 1099 D
B5/520 ePM10 60% M5 490 592 520 2800 50 D
C5/520 ePM10 60% M5 287 592 520 1700 50 D
C5-33/520 ePM10 60% M5 287 287 520 800 50 D
A5-63/520 ePM10 60% M5 592 287 520 1700 50 D
A5-65/520 ePM10 60% M5 592 490 520 2800 50 D
A5/370 ePM10 60% M5 592 592 370 3400 65 >1200 E
B5/370 ePM10 60% M5 490 592 370 2800 65 E
C5/370 ePM10 60% M5 287 592 370 1700 65 E
C5-33/370 ePM10 60% M5 287 287 370 800 65 E
A5-36/370 ePM10 60% M5 592 287 370 1700 65 E
A5-65/370 ePM10 60% M5 592 490 370 2800 65 E
A6 ePM2,5 50% M6 592 592 600 3400 70 1189 C
B6 ePM2,5 50% M6 490 592 600 2800 70 C
C6 ePM2,5 50% M6 287 592 600 1700 70 C
C6-33 ePM2,5 50% M6 287 287 600 800 70 C
A6-63 ePM2,5 50% M6 592 287 600 1700 70 C
A6-65 ePM2,5 50% M6 592 490 600 2800 70 C
UF6 ePM2,5 50% M6 592 592 600 3400 60 872 B
UG6 ePM2,5 50% M6 490 592 600 2800 60 B
UH6 ePM2,5 50% M6 287 592 600 1700 60 B
UH6-33 ePM2,5 50% M6 287 287 600 800 55 B
UF6-63 ePM2,5 50% M6 592 287 600 1700 60 B
UF6-65 ePM2,5 50% M6 592 490 600 2800 60 B
UF6/520 ePM2,5 50% M6 592 592 520 3400 65 997 C
UG6/520 ePM2,5 50% M6 490 592 520 2800 65 C
UH6/520 ePM2,5 50% M6 287 592 520 1700 65 C
UH6-33/520 ePM2,5 50% M6 287 287 520 800 65 C
UF6-63/520 ePM2,5 50% M6 592 287 520 1700 65 C
UF6-65/520 ePM2,5 50% M6 592 490 520 2800 65 C
UF6/370 ePM2,5 50% M6 592 592 370 3400 80 1167 C
UG6/370 ePM2,5 50% M6 490 592 370 2800 80 C
UH6/370 ePM2,5 50% M6 287 592 370 1700 80 C
UH6-33/370 ePM2,5 50% M6 287 287 370 800 80 C
UF6-63/370 ePM2,5 50% M6 592 287 370 1700 80 C
UF6-65/370 ePM2,5 50% M6 592 490 370 2800 80 C
A7 ES ePM1 60% F7 592 592 600 3400 95 1337 C
B7 ES ePM1 60% F7 490 592 600 2800 95 C
C7 ES ePM1 60% F7 287 592 600 1700 95 C
C7-33 ES ePM1 60% F7 287 287 600 800 95 C
A7-63 ES ePM1 60% F7 592 287 600 1700 95 C
A7-65 ES ePM1 60% F7 592 490 600 2800 95 C
UF7 ES ePM1 60% F7 592 592 600 3400 75 940 A
UG7 ES ePM1 60% F7 490 592 600 2800 75 A
UH7 ES ePM1 60% F7 287 592 600 1700 75 A
UH7-33 ES ePM1 60% F7 287 287 600 800 75 A
UF7-63 ES ePM1 60% F7 592 287 600 1700 75 A
UF7-65 ES ePM1 60% F7 592 490 600 2800 75 A
UF7/520 ES ePM1 60% F7 592 592 520 3400 85 1099 B
UG7/520 ES ePM1 60% F7 490 592 520 2800 85 B
UH7/520 ES ePM1 60% F7 287 592 520 1700 85 B
UH7-33/520 ES ePM1 60% F7 287 287 520 800 85 B
UF7-63/520 ES ePM1 60% F7 592 287 520 1700 85 B
UF7-65/520 ES ePM1 60% F7 592 490 520 2800 85 B
UF7/370 ES ePM1 60% F7 592 592 370 3400 120 1552 D
UG7/370 ES ePM1 60% F7 490 592 370 2800 120 D
UH7/370 ES ePM1 60% F7 287 592 370 1700 120 D
UH7-33/370 ES ePM1 60% F7 287 287 370 800 120 D
UF7-63/370 ES ePM1 60% F7 592 287 370 1700 120 D
UF7-65/370 ES ePM1 60% F7 592 490 370 2800 120 D
A7 ePM1 70% F7 592 592 600 3400 130 1869 D
B7 ePM1 70% F7 490 592 600 2800 130 D
C7 ePM1 70% F7 287 592 600 1700 130 D
C7-33 ePM1 70% F7 287 287 600 800 130 D
A7-63 ePM1 70% F7 592 287 600 1700 130 D
A7-65 ePM1 70% F7 592 490 600 2800 130 D
UF7 ePM1 70% F7 592 592 600 3400 110 1314 C
UG7 ePM1 70% F7 490 592 600 2800 110 C
UH7 ePM1 70% F7 287 592 600 1700 110 C
UH7-33 ePM1 70% F7 287 287 600 800 110 C
UF7-63 ePM1 70% F7 592 287 600 1700 110 C
UF7-65 ePM1 70% F7 592 490 600 2800 110 C
UF7/520 ePM1 70% F7 592 592 520 3400 125 1711 D
UG7/520 ePM1 70% F7 490 592 520 2800 125 D
UH7/520 ePM1 70% F7 287 592 520 1700 125 D
UH7-33/520 ePM1 70% F7 287 287 520 800 125 D
UF7-63/520 ePM1 70% F7 592 287 520 1700 125 D
UF7-65/520 ePM1 70% F7 592 490 520 2800 125 D
UF7/370 ePM1 70% F7 592 592 370 3400 170 >2150 E
UG7/370 ePM1 70% F7 490 592 370 2800 170 E
UH7/370 ePM1 70% F7 287 592 370 1700 170 E
UH7-33/370 ePM1 70% F7 287 287 370 800 170 E
UF7-63/370 ePM1 70% F7 592 287 370 1700 170 E
UF7-65/370 ePM1 70% F7 592 490 370 2800 170 E
UF9 ePM1 85% F9 592 592 600 3400 160 1956 D
UG9 ePM1 85% F9 490 592 600 2800 160 D
UH9 ePM1 85% F9 287 592 600 1700 160 D
UH9-33 ePM1 85% F9 287 287 600 800 160 D
UF9-63 ePM1 85% F9 592 287 600 1700 160 D
UF9-65 ePM1 85% F9 592 490 600 2800 160 D
UF9/520 ePM1 85% F9 592 592 520 3400 175 2266 D
UG9/520 ePM1 85% F9 490 592 520 2800 175 D
UH9/520 ePM1 85% F9 287 592 520 1700 175 D
UH9-33/520 ePM1 85% F9 287 287 520 800 175 D
UF9-63/520 ePM1 85% F9 592 287 520 1700 175 D
UF9-65/520 ePM1 85% F9 592 490 520 2800 175 D
 Pressure drop calculation tool is available

Calculate pressure drop

Choose a full-size filter module in the table above to calculate the pressure drop.
Full-size filter modules are typically 592x592mm for bag/panel filters and 610x610mm for HEPA filters.

Video

Specifications

Application
Comfort air conditioning applications, pre filter applications
Filter Frame
Galvanised steel
Media
Glass fiber
Max temperature (°C)
70°C
Relative Humidity
100%
Max final pressure drop, EN 13053
Initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is lower)
Dimension standard
Filter front dimensions according EN 15805
Installation options
Front and side access housings and frames are available
Max Airflow
1,25 x nominal flow

Related Products

Articles related to Hi-Flo

The forest pavillon picture.jpg

Camfil's clean air solutions at the Swedish Pavilion - EXPO 2020 Dubai

Camfil is an official sponsor of the Swedish pavilion by providing advanced clean air solutions that ensure better indoor air quality for visitors. EXPO 2020 in Dubai has started on October 1st, 2021 and will conclude on March 31st, 2022.

Innovation Technology and Research Education and Experience Air quality Take a breath Sustainability
Fotolia 52219135 Subscription Monthly XL

Understand the Challenges in the indoor environment when the outdoor temperature changes

In cold winter months, our energy and heat needs increase as the temperature drops outside. The sudden temperature change can lead to a sharp increase in pollution levels in the outdoor air. In addition, the cold itself means that we spend even more time indoors, which brings us closer to each other. Many don't understand how it affects us and our indoor environment.

Air quality Commercial and Public buildings Air cleaners and air purifiers

Why do we need a deeper connection with the air we absolutely depend upon - indoor air quality

Camfil is in the vanguard of a growing international movement to reduce the negative health effects of polluted air. As a leader in clean air solutions, we actively inform and educate customers, decision-makers, and the general public about threatening air pollutants and the tangible benefits of effective air filtration and high indoor air quality.

Air quality Take a breath Commercial and Public buildings Air cleaners and air purifiers Virus Contamination Control

Select the right air filtration solution using Life Cycle Cost

The most important task for a filter is to reduce the amount of particles and pollutants in the ventilation air, but you can also reduce your energy costs if you look at which filters you have in the property by looking at the life cycle cost.

Standard and regulations Sustainability

CamGT EPA Filters Boost Gas Turbine Performance

Hi-Flo bag air filters and CamGT EPA air filter upgrade reduces compressor efficiency degradation by 80%, slashes 3 offline filter replacements, 7 online pre-filter replacements, and 3 offline water washes per year.

Case Studies Energy and Power Systems

Odour Exasperation - Here is what you can do in your restaurant to eliminate odour nuisance & neutralize the air

Restaurants have odours coming from a variety of sources and they all have one thing in common, they spread 'air pollution'. Odours are one of the leading causes of air pollution at restaurants or food courts and the odour profile from a kitchen depends on various factors.

Air quality Commercial and Public buildings Food and beverage

Air quality recommendations for office spaces

Air quality in your office is important to protecting the health of your employees. Poor air quality can lead to an increased transmission of viruses between employees which can lead to lower productivity and increased sick days in your office

Air quality Commercial and Public buildings Air cleaners and air purifiers Virus Contamination Control

Air Quality recommendations for Meat processing FACILITY

Air quality in meat processing facilities is often the forgotten ingredient within their facility. Did you know that Meat processing factories are susceptible to the spread of airborne viruses and microbes? The temperature and humidity requirements along with the production processes lend to the survival of airborne microbes and viruses. This means that the airborne viruses can survive longer in the air than in other facilities.

Air quality Food and beverage Air cleaners and air purifiers Virus Contamination Control

Air Quality recommendations for hotels

Air quality has always been an important factor for hotels, whether it has been removing odours from kitchen extracts to ensuring a clean environment by reducing particulate levels.

Air quality Commercial and Public buildings Air cleaners and air purifiers Virus Contamination Control

GLOBAL FAST FOOD RESTAURANT is using dynamic clean air solutions in china

Fast food stores are usually located in a crowded commercial area or building where there are problems such as polluted air, gases, and odours. The fresh air fan units in the ventilation system are often close to the pollution source, i.e., exhaust air of other shops in the building.

Case Studies Commercial and Public buildings

EGAT North Power Generation Shifted to CamGT Filters and Saved $1.24M USD in Yearly Power Degradation

Egat North, the largest energy producer in Thailand, upgraded to Hi-Flo and CamClose air intake pre-filters as well as CamGT final EPA air filters and lowered degradation by 70%, reduced water wash requirements, and saved approximately $1.24M USD per year.

Case Studies Energy and Power Systems

Dalkia Power Saves €172 000 / season with Camfil E10 EPA Filters

Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.

Case Studies Energy and Power Systems

Norland Managed Services

Case Study: Indoor Air Quality Worth The Investment. This major bank is one of the world‘s largest financial institutions. Norland Managed services are the Facilities Management provider for their 600,000 square feet London office building, in central London.

Case Studies

Camfil ProSafe 

Some processes are more sensitive than others. If you work in the food and beverage or life science industries, you know how tough the demands on clean air are. To be sure you have the right filter, look for the ProSafe symbol.

Standard and regulations Life science and healthcare Food and beverage

Camfil Serves Up Savings in Energy, Filter Costs, and Labour

Case Study: Filter Savings At Frozen Food Manufacturer. Three air handling units supplied air to critical processing areas in one of the USA's largest frozen food manufacturing facilities. The pre and final filter combination saved the plant over $33,000 per year.

Case Studies