CamCarb XG

A conical, corrosion resistant molecular filter filled with Camfil's activated alumina or activated carbon. They are the most versatile gas-phase air filters installed in supply, recirculation, and exhaust air systems for commercial, industrial, and process applications. The design provides the lowest total cost of ownership for the removal of corrosive, odorous, and irritant gases.

  • The conical shape provides the highest removal efficiency and lowest pressure drop
  • 30% lighter than metal cylinders
  • Ergonomic filter design for improved handling
  • Inherently leak-free design when installed in dedicated hardware
  • Corrosion resistant and low-dusting construction
  • Predicted removal efficiency and lifetime by Camfil's proprietary software
  • Typical target gases: hydrogen sulfide, VOCs, ozone, formaldehyde, nitrogen dioxide, and other acids and bases
  • ICON6 Molecular
  • ICON16 Large air volume
  • ICON14 IAQ_Facility
  • ICON4 IAQ_Museums
  • ICON37 ISO10121
Item Type Airflow (m3/h) Pressure drop Initial (Pa) Nominal weight (kg) Nominal weight (lbs) Optimum RH (%) Optimum temperature (°C) Optimum temperature (°F) ISO 10121 Ozone ISO 10121 NO₂ ISO 10121 SO₂ ISO 10121 Toluene
CC XG 2600 VOC_O3_NO2_SO2 2500 85 2.3 5.1 0-70 Max. 40 Max. 104 HD 95 HD 70 HD 85 HD 95
CC XG 2600 SO2_H2S^³ 2500 85 3.5 7.8 40-90 10-60 50 -140 - - - -
CC XG 2600 Acids_H2S^³ 2500 85 3.5 7.8 40-90 10-60 50 -140 - - - -
CC XG 2600 VOC 2500 95 2.3 5.1 0-70 Max. 40 Max. 104 - - - -
CC XG 2600 H2S_Mercaptans 2500 95 2.4 5.3 40-90 10-60 50-140 - - - -
CC XG 2600 Acids 2500 95 2.7 6.0 40-90 10-60 50-140 - - - -
CC XG 2600 VOC_O3_Acid_H2S 2500 95 2.9 6.4 40-70 10-40 50-104 - - - -
CC XG 2600 Bases 2500 95 2.7 6.0 40-90 10-60 50-140 - - - -
CC XG 3500 VOC_O3_NO2_SO2 3400 125 2.9 6.4 0-70 Max. 40 Max. 104 HD 95 HD 70 HD 85 HD 95
CC XG 3500 SO2_H2S^³ 3400 120 4.4 9.8 40-90 10-60 50-140 - - - -
CC XG 3500 Acids_H2S^³ 3400 120 4.4 9.8 40-90 10-60 50-140 - - - -
CC XG 3500 VOC 3400 125 2.9 6.4 0-70 Max. 40 Max. 104 - - - -
CC XG 3500 H2S_Mercaptans 3400 125 3.0 6.7 40-90 10-60 50-140 - - - -
CC XG 3500 Acids 3400 125 3.3 7.5 40-90 10-60 50-140 - - - -
CC XG 3500 VOC_O3_Acid_H2S 3400 125 3.7 8.2 40-70 10-40 50-104 - - - -
CC XG 3500 Bases 3400 125 3.4 7.5 40-90 10-60 50-140 - - - -

Video

Specifications

Application
The most reliable molecular filter for high efficiency and long-term control of molecular contaminants in sensitive buildings and process industries.
They may also be used in odor removal applications in pulp and paper mills and wastewater treatment plants, or lighter applications such as airports, cultural heritage buildings, and commercial offices.
Filter Frame
ABS
Media
Activated Carbon, Impregnated Activated Carbon, Impregnated Activated Alumina
Gasket
Outlet seal, molded TPE
Installation options
Front access frames and side access housings are available. See related products below.
Comment
Universal mounting knobs to accommodate 1.5 or 2 mm baseplates.
Sixteen (16) XG's are applied per 24" x 24" (610 x 610mm) opening.
Length and diameter of XG2600 = 18" x 5.75" (452mm x 146mm) and XG3500 = 24" x 5.75" (595mm x 146mm)
Can be filled with any loose-fill molecular media.
Max temperature (°C)
80
Max Temperature (°F)
176

Related Products

Articles related to CamCarb

Gas turbine filter testing

The test rig has been calibrated according to standards EN 779, ISO 16890 and ASHRAE 52.2 and was developed for air filter testing simulating the harsh climate conditions where gas turbines are often located.

Education and experience
CamCarb XG – best-in-class molecular carbon air filter delivers the highest gaseous contaminant removal

CamCarb XG

CamCarb XG - engineered for energy and maintenance cost savings in molecular contamination control applications

Food and beverage Electronics and optics Commercial and public buildings

Molecular filtration removes VOLATILE ORGANIC COMPOUNDS from the printing process exhaust in Thailand

S.Silpa Co., Ltd., Thailand faced constant odor nuisance and high VOC levels in their factory. This is due to the usage of various chemicals in the printing process that generate volatile organic compounds (VOCs) when exposed to heat, such as thinner solutions, alcohols, inks, cleaning solvents, vinyl sheets.

Air quality Manufacturing and machinery Case studies

Molecular air filtration in life sciences & healthcare

Awareness and regulations in the life sciences and pharmaceutical processes are essential as critical molecules in the mistaken place can cause failure of the production process which can be extremely harsh to the outcome. In the pharmaceutical and life sciences industries, cleanrooms and laboratories are often used for various purposes. These cleanrooms are subject to a high level of cleanliness of numerous particles and molecules

Air quality Life science and healthcare

"airplane jet engines don't use filters, so why should i?"

To answer this question, let's look at the difference between a land based gas turbine and a jet engine.

Energy and Power Systems

Camfil measures air on hornsgatan

For several years, Hornsgatan has been designated Sweden's dirtiest street when it comes to air pollution. Hornsgatan is an exposed street when it comes to harmful particles in the air. How does this affect residents?

Air quality Case studies

Mold odor

Aftermath of flooding driver government office to turn to CamCleaner vertical air cleaners for eliminating mold odor

Air cleaners and air purifiers Case studies

Watch and learn

If you are looking to expand your knowledge on the impact of air filtration on your gas turbines and other turbomachinery, look no more!

Education and experience Energy and Power Systems

Have questions? Need information?
Product & Industry Information
(888) 599-6620
Other inquiries
(973) 616-7300
Find a contact