CamPulse GT Polytech HE

The PolyTech HE HemiPleat is a self cleaning air filter for gas turbines. A high efficiency filter, it has a propriety media blend and a moisture resistant silicone treatment that offer optimum dust release, yielding long service life at high filtration efficiencies. They offer excellent protection in most high dust environments.

  • Self-cleaning cartridge filter with longer filter life and lower initial pressure drop
  • Extends final filter life when used as a pre-filter
  • Good pulsability
  • Recommended as a pre-filter, not recommended as a final filter
  • ICON17 2in1
  • ICON54 ISO 29461 icon
Item Type ISO 29461 Filter Class ASHRAE Airflow (m3/h) Diameter 1 (mm) Diameter 2 (mm) Length 1, Cylindrical (mm) Length 2, Cylindrical (mm) Pressure drop Initial (Pa)
CamPulse Cyl/Cyl T5 MERV 16 2500 445 324 660 660 140
CamPulse Co/Cyl T5 2500 445/324 324 660 660 165
Tenkay 34" T5 1150 324 864 147

Specifications

Application
Desert and arctic environments, heavy dust load areas
Pre-filter for gas turbines, large industrial air compressores, diesel & gas engines, generators & enclosures
Filter Frame
Galvanized steel, Stainless steel
Media
Synthetic
Relative Humidity
100%
Recommended final pressure drop
1000 Pa
Pleat
HemiPleat
Separator
Hot-melt
Gasket
Polyurethane, endless foamed, EPDM
Sealant
Polyurethane
Comment
Additional information: Available as dimple pleated and in fire retardant version on request.

Additional product features:
Patented proven open-pleat media HemiPleat™ technology
Water repellent media protected by metal liners
Galvanized metal finish
Self-cleaning air filter cartridges
Improved air distribution
Suitable also in high humidity conditions
Suitable as prefilter for filter classes T10, T12
Tenkays are available with the Gold Cone option for improved pulsing.
Gold series cartridges available
Other filter sizes are available. Contact us for more information.
Retrofit filters are also available for all competitor housings.
Filter wraps available on demand
Max temperature (°C)
70º C

Articles related to Blended

Camfil measures air on hornsgatan

For several years, Hornsgatan has been designated Sweden's dirtiest street when it comes to air pollution. Hornsgatan is an exposed street when it comes to harmful particles in the air. How does this affect residents?

Air quality Case studies
"Airplane jet Engines don't use filters, so why should I?"

"airplane jet engines don't use filters, so why should i?"

To answer this question, let's look at the difference between a land based gas turbine and a jet engine.

Energy and Power Systems

Watch and learn

If you are looking to expand your knowledge on the impact of air filtration on your gas turbines and other turbomachinery, look no more!

Education and experience Energy and Power Systems

Gas turbine filter testing

The test rig has been calibrated according to standards EN 779, ISO 16890 and ASHRAE 52.2 and was developed for air filter testing simulating the harsh climate conditions where gas turbines are often located.

Education and experience

Have questions? Need information?
Product & Industry Information
(888) 599-6620
Other inquiries
(973) 616-7300
Find a contact