To meet increasing demands for performance, Camfil has developed the CamGT 4V-300 turbine air intake filters. The result is a high-performing static filter that extends turbine life, decreases maintenance, and reduces carbon footprint with EPA filters. It is suitable for all installations where safety/reliability is important, including corrosive/humid/wet conditions.
Item Type | ISO 29461 | ISO/PM rating | Filter Class EN779 | Filter Class EN1822 | Filter Class ASHRAE | Width (mm) | Height (mm) | Depth (mm) | Airflow (m3/h) | Pressure drop Initial (Pa) |
---|---|---|---|---|---|---|---|---|---|---|
CamGT 4V-300 | Coarse 60% | M6 | MERV 13 | 592 | 592 | 300 | 4250 | 105 | ||
4V-300-T7-Std | T7 | ePM1 70% | F7 | MERV 13 | 592 | 592 | 300 | 4250 | 130 | |
4V-300-T7-XL | T7 | ePM1 70% | F7 | MERV 13 | 592 | 592 | 300 | 4250 | 125 | |
4V-300-T8 | T8 | ePM1 80% | F8 | MERV 14 | 592 | 592 | 300 | 4250 | 140 | |
4V-300-T8-XL | T8 | ePM1 80% | F8 | MERV 14 | 592 | 592 | 300 | 4250 | 135 | |
4V-300-T9 | T9 | ePM1 85% | F9 | MERV 15 | 592 | 592 | 300 | 4250 | 165 | |
4V-300-T9-XL | T9 | ePM1 85% | F9 | MERV 15 | 592 | 592 | 300 | 4250 | 160 | |
4V-300-T10 | T10 | E10 | 592 | 592 | 300 | 4250 | 200 | |||
4V-300-T11 | T11 | E11 | 592 | 592 | 300 | 4250 | 225 | |||
4V-300-T12 | T12 | E12 | 592 | 592 | 300 | 3400 | 260 |
CamGT filters have been engineered to excel in extreme environments. They virtually eliminate fouling, corrosion and maintenance downtime, all at a lower and more stable pressure drop.
Energy and Power SystemsA leading steel producer upgraded blower filtration, extending final filter life by 16x, pre-filter life by 4x, and achieving 100% operational availability.
Energy and Power Systems Case studiesA cogeneration plant operating 368MW gas turbines in Singapore suffered from availability, reliability, and efficiency issues. To improve the situation, it needed to upgrade its air-inlet filters. Camfil performed on-site and Life Cycle Cost analyses to recommend a solution appropriate for the challenging site conditions.
Designed to help identify filters that improve gas turbine efficiency, The Value Rating system is the easiest way to select air filter for gas turbines.
The CamGT air filter line has been turbo-boosted to maximize power, profits, and uptime of your gas turbine.
With a growing demand for greener practices, and rising operational costs, it has become imperative that gas turbine operators cut their carbon footprints. Upgraded air intake systems are one of the easiest, most cost-effective ways to meet these demands, while improving operations at the same time.
Camfil designs a static EPA retrofit gas turbine filtration solution for LM6000 turbines to ensure they deliver reliable power & heating to the district. The result of the upgrade was 3x more filter life, reduction in CO2 emissions by 1 100 tons per year, and fuel consumption savings of 650 000 Sm3 per year.
Upgrade your gas turbine air inlet filters to cut carbon emissions per MWh produced.
Located offshore Ivory Coast, Africa, the CamGT EPA filter solution saves Foxtrot International 3 shutdowns per year and eliminates salt corrrosion, without compromising on footprint.
Noise complaints from neighboring communities in Thailand prompted the plants to evaluate a noise-reducing filtration system. The CamGT high efficiency air filter solution not only improved the noise levels, it also increased turbine availability, improved pressure drop and helped the gas turbine produce more power.
Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.
Tata Power Ltd, India's largest integrated power company requests Camfil for a Cam-Flo pocket bag filter and CamGT static air filter retrofit after heavy hot corrosion in the gas turbine and high pressure drop jeopardized performance and safety.