CamGT 4V-300

To meet increasing demands for performance, Camfil has developed the CamGT 4V-300 turbine air intake filters. The result is a high-performing static filter that extends turbine life, decreases maintenance, and reduces carbon footprint with EPA filters. It is suitable for all installations where safety/reliability is important, including corrosive/humid/wet conditions.

  • Hydrophobic filter construction and media
  • Low operational pressure drop, even when wet, with patented built-in drainage
  • Sealed on all sides and featuring our patented double sealing process
  • Resistant to turbulence and extreme pressure drop
  • Patented Aerodynamic support grid for lower pressure drop
  • Optimized media area for the lowest pressure drop at EPA efficiency
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5 Low Pressure Drop
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
  • ICON54 ISO 29461 icon
Item Type ISO 29461 ISO/PM rating Filter Class EN779 Filter Class EN1822 Filter Class ASHRAE Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
CamGT 4V-300 Coarse 60% M6 MERV 13 592 592 300 4250 105
4V-300-T7-Std T7 ePM1 70% F7 MERV 13 592 592 300 4250 130
4V-300-T7-XL T7 ePM1 70% F7 MERV 13 592 592 300 4250 125
4V-300-T8 T8 ePM1 80% F8 MERV 14 592 592 300 4250 140
4V-300-T8-XL T8 ePM1 80% F8 MERV 14 592 592 300 4250 135
4V-300-T9 T9 ePM1 85% F9 MERV 15 592 592 300 4250 165
4V-300-T9-XL T9 ePM1 85% F9 MERV 15 592 592 300 4250 160
4V-300-T10 T10 E10 592 592 300 4250 200
4V-300-T11 T11 E11 592 592 300 4250 225
4V-300-T12 T12 E12 592 592 300 3400 260
 Pressure drop calculation tool is available

Calculate pressure drop

Choose a full-size filter module in the table above to calculate the pressure drop.
Full-size filter modules are typically 592x592mm for bag/panel filters and 610x610mm for HEPA filters.

Video

Specifications

Application
All installations where safety/reliability/long life is important, especially areas with high humidity/heavy rain
Pre- or final filter for gas turbines, large industrial air compressors, diesel & gas engines, generators & enclosures, wind turbines
Filter Frame
Plastic moulded, ABS
Media
Glass fiber
Max temperature (°C)
70°C
Relative Humidity
100%
Recommended final pressure drop
600 Pa
Separator
Hot-melt
Gasket
Polyurethane, endless foamed
Grille, Downstream
Support grid for filtermedia
Sealant
Polyurethane
Max Airflow
1,3 x nominal flow
Comment
Fire rating: Available according to DIN4102 class b2 rating on request
Burst strength: > 6250 Pa continuous wet/soaked
Reverse flow version: With support grid available on request
Additional information: Also available in 1/2 and 3/4 size on request.
Filter Class ASHRAE
MERV 13

Related Products

Articles related to CamGT

Infographic: TurboBoost Performance - Boost power • Boost uptime • boost profits

CamGT filters have been engineered to excel in extreme environments. They virtually eliminate fouling, corrosion and maintenance downtime, all at a lower and more stable pressure drop.

Energy and Power Systems

Enhancing steel mill availability with filters

A leading steel producer upgraded blower filtration, extending final filter life by 16x, pre-filter life by 4x, and achieving 100% operational availability.

Energy and Power Systems Case studies

Singapore coastal cogeneration plant camgt

A cogeneration plant operating 368MW gas turbines in Singapore suffered from availability, reliability, and efficiency issues. To improve the situation, it needed to upgrade its air-inlet filters. Camfil performed on-site and Life Cycle Cost analyses to recommend a solution appropriate for the challenging site conditions.

Energy and Power Systems Case studies

Infographic - the easiest way to select air filters for gas turbines

Designed to help identify filters that improve gas turbine efficiency, The Value Rating system is the easiest way to select air filter for gas turbines.

Energy and Power Systems

TurboBoost: CamGT filter line

The CamGT air filter line has been turbo-boosted to maximize power, profits, and uptime of your gas turbine.

Energy and Power Systems

Whitepaper: cutting the carbon cost with improved air inlet systems 

With a growing demand for greener practices, and rising operational costs, it has become imperative that gas turbine operators cut their carbon footprints. Upgraded air intake systems are one of the easiest, most cost-effective ways to meet these demands, while improving operations at the same time.

Energy and Power Systems

Gas Turbines Breathe New Life

Camfil designs a static EPA retrofit gas turbine filtration solution for LM6000 turbines to ensure they deliver reliable power & heating to the district. The result of the upgrade was 3x more filter life, reduction in CO2 emissions by 1 100 tons per year, and fuel consumption savings of 650 000 Sm3 per year.

Energy and Power Systems Case studies

Upgrade GT filtration to slash carbon emissions 

Upgrade your gas turbine air inlet filters to cut carbon emissions per MWh produced.

Energy and Power Systems

Camfil Designs a Compact Solutions on Existing Offshore Platform for Foxtrot International that Reduces Gas Turbine Maintenance

Located offshore Ivory Coast, Africa, the CamGT EPA filter solution saves Foxtrot International 3 shutdowns per year and eliminates salt corrrosion, without compromising on footprint.

Energy and Power Systems Case studies

Camgt 4v300

Noise complaints from neighboring communities in Thailand prompted the plants to evaluate a noise-reducing filtration system. The CamGT high efficiency air filter solution not only improved the noise levels, it also increased turbine availability, improved pressure drop and helped the gas turbine produce more power.

Energy and Power Systems Case studies

Dalkia power saves €172 000 / season with camfil e10 epa filters

Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.

Energy and Power Systems Case studies

Tata power trombay retrofits their filtration system to improve corrosion, pressure drop, and diverter dampers within deadline

Tata Power Ltd, India's largest integrated power company requests Camfil for a Cam-Flo pocket bag filter and CamGT static air filter retrofit after heavy hot corrosion in the gas turbine and high pressure drop jeopardized performance and safety.

Energy and Power Systems Case studies

Call Kuala Lumpur Office
+603 8023 8250
Call Penang Office
+604 642 5004
Find a contact