Megalam ProSafe

  • Compliant to VDI 6022
  • Microbial inert components acc. to ISO 846
  • Tested for Food Contact acc. to EC 1935:2004
  • Free of bisphenol-A, phthalate and formaldehyde
  • Chemically resistant to inactivation and cleaning agents
  • ICON9 en1822
  • ICON20 prosafe
  • ICON22 creo
  • ICON42 UL logo
Item Type Filter Class EN1822 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
Megalam MD15-305x610-10/22 U15 305 610 66 300 140
Megalam MD15-610x610-10/22 U15 610 610 66 600 140
Megalam MD15-1219x610-10/22 U15 1219 610 66 1205 145
Megalam MX15-305x610-10/22 U15 305 610 90 300 125
Megalam MX15-914x610-10/22 U15 914 610 90 905 115
Megalam MX15-610x610-10/22 U15 610 610 90 605 115
Megalam MX15-1219x610-10/22 U15 1219 610 90 1205 115
Megalam MG15-610x610-10/22 U15 610 610 110 603 80
Megalam MG15-305x610-10/22 U15 305 610 110 301 90
Megalam MG15-914x610-10/22 U15 914 610 110 905 80
Megalam MG15-1219x610-10/22 U15 1219 610 110 1205 80
Megalam MD14-305x610-10/22 H14 305 610 66 300 120
Megalam MD14-610x610-10/22 H14 610 610 66 600 120
Megalam MD14-914x610-10/22 H14 914 610 66 905 140
Megalam MD14-1219x610-10/22 H14 1219 610 66 1205 140
Megalam MX14-305x610-10/22 H14 305 610 90 300 105
Megalam MX14-610x610-10/22 H14 610 610 90 605 95
Megalam MX14-914x610-10/22 H14 914 610 90 905 95
Megalam MX14-1219x610-10/22 H14 1219 610 90 1205 95
Megalam MG14-305x610-10/22 H14 305 610 110 302 75
Megalam MG14-610x610-10/22 H14 610 610 110 605 65
Megalam MG14-914x610-10/22 H14 914 610 110 905 64
Megalam MG14-1219x610-10/22 H14 1219 610 110 1205 64
MD13- 305x610-10/22 H13 305 610 66 301 116
MD13- 610x610-10/22 H13 610 610 66 603 115
MD13- 914x610-10/22 H13 914 610 66 903 114
MD13- 1219x610-10/22 H13 1219 610 66 1205 114
MD13- 610x610x76-11/22 H13 610 610 76 603 118
Megalam MD13LS-305x610x71-10/22 H13 305 610 71 301 116
Megalam MD13LS-610x610x71-10/22 H13 610 610 71 603 115
Megalam MD13LS-914x610x71-10/22 H13 914 610 71 903 114
Megalam MD13LS-1219x610x71-10/22 H13 1219 610 71 1205 114
Megalam MD15-914x610-10/22 H13 914 610 66 903 145

Specifications

Application
Hepa/ULPA filter for clean rooms and LAF benches
Frame
Anodized aluminium
Media
Glass fiber
Max temperature °C
70 °C
Relative Humidity
100%
Recommended final pressure drop
2x Initial pressure drop
Separator
Hot Melt
Gasket
Silicone Gel, Polyurethane, endless foamed
Grille, Downstream
Expanded metal painted (RAL 9010)
Grille, Upstream
Expanded metal painted (RAL 9010)
Sealant
Polyurethane
Max Airflow
Nominal flow rate (if not, efficiency drops)
Comment
Individually scan-tested acc. EN 1822:2009 with protocol and packed in PE-foil. Compliant with Prosafe requirements. Other editions on request.

Articles related to Megalam

Hospitals & Healthcare: St. James Hospital Dublin

Case Study: St James Hospital Prevents Aspergillus. Healthcare facilities must maintain the highest levels of cleanliness to promote health and healing. Camfil provides air cleaners for these environments. St. James Hospitaal in Dublin used Camfil for Aspergillus prevention.

Case Studies

Food & Beverage: World's Leading Beverage Company

Case Study: Clean Air For Leading Beverage Manufacturer. Air is the only ingredient involved in every aspect of food and beverage manufacturing. Air comes into contact with products from storage of goods all way to packaging. How can we help to keep your food processes safe?

Camtain® Contains Explosive Pharma Dust

Case Study: Camtain Contains Explosive Pharma Dust. A multinational pharmaceutical company needed a dust extraction system for their new tableting suite in Spain. The suite comprised of six rooms, each with its own tablet machine that created explosive dusts.

Case Studies

UNIVERSITY SEES PROOF OF 24% LOWER ANNUAL ENERGY COSTS USING CAMFIL FILTER VS COMPETING FILTER

Case Study: Energy Savings At Western United States University. A Life Cycle Costing (LCC) analysis proved the Camfil Durafil filter operated at a 24% lower energy cost per year than the Viledon T-60. The Camfil product would save the customer $14 per filter per year versus the alternative.

Case Studies

SCHOOL LEARNS THE BENEFIT OF FRESH AIR

Case Study: School Learns the Benefit of Clean Air. Camfil worked with a school to help improve the indoor air quality for students during the critical exam period. They provided the school with Camfil air purifiers for use in their gymnasium where students sit their exams.

Case Studies

Call Kuala Lumpur Office
+603 8023 8250
Call Penang Office
+604 642 5004
Find a contact