CamGT 3V-600

  • 超大的滤料面积可达到长寿命、大风量应用
  • 过滤效率高(最高达H13)
  • 专利垂直密褶
  • 低阻力(dP),最佳运行经济性的产品
  • 坚固的HEPA型框架消除泄漏风险
  • 专利的空气动力学面板
  • 满足行业最严格的要求
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5 Low Pressure Drop
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
ISO16890 过滤器等级 EN779 过滤器等级 EN1822 Filter Class ASHRAE 宽度 (mm) 高度 (mm) 深度 (mm) 风量 (m3/h) 初阻力 (Pa)
ePM1 80% F8 MERV 14 592 592 600 4250 100
ePM1 85% F9 MERV 15 592 592 600 4250 115
E10 592 592 600 4250 135
E11 592 592 600 4250 140
E12 592 592 600 4250 190
 阻力计算工具

计算阻力

m3/h
= Pa
风量过大

规格参数

应用
适用于高安全性/可靠性需求应用,同时实现低阻力、高容尘量、长寿命
外框
一体成型塑料
滤材
玻璃纤维
最高温度 (°C)
70°C
相对湿度
100%
推荐终阻力
600 Pa
分隔物
热熔胶
密封垫
无接缝发泡聚氨酯
护网, 下游
滤材表面护网支撑
密封胶
聚氨酯
最大风量
1,8 x 额定风量
评论
爆裂强度:> 6250 Pa,高湿度环境连续运行
Filter Class ASHRAE
MERV 14

Articles related to CamGT

Significant Reduction in Compressor Efficiency Degradation

CamGT EPA Filters Boost Gas Turbine Performance

Hi-Flo bag air filters and CamGT EPA air filter upgrade reduces compressor efficiency degradation by 80%, slashes 3 offline filter replacements, 7 online pre-filter replacements, and 3 offline water washes per year.

Energy and Power Systems Case Studies
Infographic - The easiest way to select air filters for gas turbines

Infographic - The easiest way to select air filters for gas turbines

Designed to help identify filters that improve gas turbine efficiency, The Value Rating system is the easiest way to select air filter for gas turbines.

Energy and Power Systems

Infographic: TurboBoost Performance - Boost power • Boost uptime • boost profits

CamGT filters have been engineered to excel in extreme environments. They virtually eliminate fouling, corrosion and maintenance downtime, all at a lower and more stable pressure drop.

Energy and Power Systems

Whitepaper: Gas Turbine Hot Corrosion

Hot corrosion is a source of nonrecoverable degradation on gas turbines. It is a chemical reaction between salts, sulfur and heat, where the damages can reduce an engine’s life by up to 75%. One of the most effective methods is to eliminate the contaminants triggering the chemical reaction. This paper examines the causes of hot corrosion and assesses various methods of mitigation.

Energy and Power Systems

Say Goodbye to Fouling and Pressure Spikes!

CamGT 3V-600 static final filters and Cam-Flo GT Hybrid pocket air filters eliminate 6 offline washes per year, improve gas turbine compressor efficiency, and boost power output for a Singaporean coastal cogeneration power plant.

Energy and Power Systems Case Studies

EGAT North Power Generation Shifted to CamGT Filters and Saved $1.24M USD in Yearly Power Degradation

Egat North, the largest energy producer in Thailand, upgraded to Hi-Flo and CamClose air intake pre-filters as well as CamGT final EPA air filters and lowered degradation by 70%, reduced water wash requirements, and saved approximately $1.24M USD per year.

Energy and Power Systems Case Studies

Combined Cycle Plant installs a CamLab on-site for 3 months to test filters & LCC shows $900 000 USD savings over a 6-year timeframe

Egat North, the largest energy producer in Thailand, upgraded to Hi-Flo and CamClose air intake pre-filters as well as CamGT final EPA air filters and lowered degradation by 70%, reduced water wash requirements, and saved approximately $1.24M USD per year.

Manufacturing and Machinery Energy and Power Systems Case Studies

An LNG Plant with high availability & reliability requirements upgrades to the CamGT EPA filters

Air sampling, CamLab on-site analysis, as well as a Life Cycle Cost analysis show that the CamGT EPA filters will result in no shutdowns for turbine water washes, final filter shutdown extended to 5 years, decreased risk of corrosion and maximum power output.

Energy and Power Systems Case Studies

A Pacific Coast Energy Plant Operates Corrosion-Free with Stable Output After Corrosion Tests Show the Benefits of EPA filters

An energy plant on the pacific coast upgrades their Siemens 501F gas turbine filtration to the CamGT 4V-300 air intake filters after tests show its water and salt handling capabilities.

Energy and Power Systems Case Studies

Engie Midlothian Air Intake Retrofit Means No Filter Change-Out for 3 years for 6 Alstom Gas Turbines 

Camfil provides the CamGT EPA air filter solution that helps reduce gas turbine compressor efficiency degradation and improves pressure drop by 40%. Three years after installation, the customer reported no filter change-outs, only 1 water wash in 3 years, and a low and stable pressure drop.

Energy and Power Systems Case Studies

Retrofit of a Thailand Offshore Air Intake Filter System Improves gas turbine efficiency, Reduces Engine Degradation, Optimizes Turbine Maintenance, and Increases Uptime with high efficiency filters

Frequent pressure and short filter replacement intervals led to high operational costs. Camfil's Cam-Flo air intake pre-filters and CamGT EPA air filters met their goal of 8000 hours of life and reduced pressure drop by 50%.

Manufacturing and Machinery Energy and Power Systems Case Studies

TurboBoost: CamGT Filter Line

The CamGT air filter line has been turbo-boosted to maximize power, profits, and uptime of your gas turbine.

Energy and Power Systems

BOOST TO REDUCE 减少碳排放

升级燃气轮机过滤系统,减少每MWh的碳排放

Energy and Power Systems

Tata Power Trombay 改造

Tata Power Ltd, India's largest integrated power company requests Camfil for a Cam-Flo pocket bag filter and CamGT static air filter retrofit after heavy hot corrosion in the gas turbine and high pressure drop jeopardized performance and safety.

Energy and Power Systems Case Studies

Dalkia Power Saves €172 000 / season with Camfil E10 EPA Filters

Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.

Energy and Power Systems Case Studies

CamGT static filters reduce noise & bring additional profits due to lower pressure drop

Noise complaints from neighboring communities in Thailand prompted the plants to evaluate a noise-reducing filtration system. The CamGT high efficiency air filter solution not only improved the noise levels, it also increased turbine availability, improved pressure drop and helped the gas turbine produce more power.

Energy and Power Systems Case Studies

Camfil Designs a Compact Solutions on Existing Offshore Platform for Foxtrot International that Reduces Gas Turbine Maintenance

Located offshore Ivory Coast, Africa, the CamGT EPA filter solution saves Foxtrot International 3 shutdowns per year and eliminates salt corrrosion, without compromising on footprint.

Energy and Power Systems Case Studies