CamGT 4V-300

  • 专利的点断式热熔胶垂直密褶保证排水顺畅
  • 过滤效率高(最高H13)
  • 抗水性滤材
  • 潮湿环境下保持低阻力
  • 坚固的HEPA型框架
  • 双重密封制造避免空气旁通泄漏
  • 满足行业最高规格要求
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
ISO16890 过滤器等级 EN779 过滤器等级 EN1822 Filter Class ASHRAE 宽度 (mm) 高度 (mm) 深度 (mm) 风量 (m3/h) 初阻力 (Pa)
ePM1 75% F7 MERV 13 592 592 292 4250 135
ePM1 75% F7 MERV 13 592 592 292 4250 125
ePM1 80% F8 MERV 14 592 592 292 4250 145
ePM1 80% F8 MERV 14 592 592 292 4250 135
ePM1 85% F9 MERV 15 592 592 292 4250 170
ePM1 85% F9 MERV 15 592 592 292 4250 160
E10 592 592 292 4250 210
E11 592 592 292 4250 230
E12 592 592 292 4250 310
 阻力计算工具

计算阻力

m3/h
= Pa
风量过大

规格参数

应用
适用于注重安全/可靠性的设施
外框
一体成型塑料
滤材
玻璃纤维
最高温度 (°C)
70°C
相对湿度
100%
推荐终阻力
600 Pa
分隔物
热熔胶
密封垫
无接缝发泡聚氨酯
护网, 下游
滤材表面护网支撑
密封胶
聚氨酯
最大风量
1,3 x 额定风量
评论
阻燃等级:可根据要求提供DIN4102 b2等级
耐破度:浸湿条件下,> 6250 Pa
反装型号:根据要求提供支持护网
其他信息:可根据要求提供1/2和3/4尺寸。

Articles related to CamGT

BOOST TO REDUCE 减少碳排放

升级燃气轮机过滤系统,减少每MWh的碳排放

Energy and Power Systems

Dalkia Power Generation

Case Study: Dalkia, a leader in the French gas turbine market, launched a national comparative test to increase power production by improving air filtration efficiency.

Manufacturing and Machinery Case Studies

Gulf of Thailand Oil and Gas

Case Study: One of the world's Oil & Gas majors had severe problems associated with the operation of their gas turbines. Frequent peaks in inlet air pressure and short filter replacement intervals led to high operational costs.

Case Studies Energy and Power Systems

Pacific Coast Energy Plant

Case Study: An energy plant on the pacific coast upgrades to the camgt 4v-300 air inlet filters after tests show its water and salt handling capabilities.

Case Studies Energy and Power Systems

LNG & Air Filtration

Case Study: Achieving high reliability and availability compression systems for LNG export sites.

Case Studies Energy and Power Systems

Plant upgrades to the camGT 3V-600 for a 6-year lifecycle & to prevent engine degradation

Case Study: Comparison Test indicates a potential of $937 000 USD savings over a six-year timeframe by upgrading to EPA.

Case Studies Energy and Power Systems

EGAT North Power Generation

Case Study: EGAT North shifted to Camfil Filters and saved $1.4M USD in Yearly Power Degradation.

Case Studies Energy and Power Systems

solar turbines & Camfil design a  SOLUTION FOR OFFSHORE PLATFORM

Case Study: The units are exposed to harsh environmental conditions that lead to spikes in pressure drop (dP) and excessive engine degradation from fouling and corrosion. As a result, the customer was forced to schedule unwanted shutdowns for maintenance.

Case Studies Energy and Power Systems

CamGT Filters Reduce Noise & Bring Additional Profits Due To Lower Pressure Drop

Case Study: Noise complaints from neighboring communities prompted the plants to evaluate a noise-reducing filtration system.

Case Studies Energy and Power Systems

Dalkia Upgrades To EPA Class

Case Study: Camfil Wins Dalkia Over Four Competitors. Dalkia designed 12 testing benches to compare four air filtration combinations on three sites in France with different operating environments. Four competitors were free to select their best combinations.

Case Studies Energy and Power Systems

Tata Power Trombay 改造

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies Energy and Power Systems