Dual10

  • Moisture resistant frame board
  • Diagonal Support
  • Radial Pleats
  • Proprietary Dual High Lofted Fibers
  • Welded Steel Grid with Corrosion Inhibitor
  • Built Strong
  • ICON7 iso16890.ai
  • ICON42 UL logo
Item Type ISO/PM rating Filter Class ASHRAE Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa) Energy (kWh/year) Energy Class (Eurovent)
Dual10 24x24x2 ePM10 55% MERV 9 594 594 44 3400 75 1008 D
Dual10 24x20x2 ePM10 55% MERV 9 495 594 44 2839 75 D
Dual10 24x12x2 ePM10 55% MERV 9 289 594 44 1700 75 D
Dual10 20x20x2 ePM10 55% MERV 9 495 495 44 2363 75 D
Dual10 24x24x4 ePM10 55% MERV 9 594 594 95 3400 68 1020 D
Dual10 24x20x4 ePM10 55% MERV 9 492 594 95 2839 68 D
Dual10 20x20x4 ePM10 55% MERV 9 492 492 95 2363 68 D
Dual10 24x12x4 ePM10 55% MERV 9 289 594 95 1700 68 D

Specifications

Application
Prevention of dust and dirt build up on heating/cooling coils within ventilation systems
Frame
Water resistant cardboard
Media
Dual layered, blended polyester
Max temperature °C
70ºC
Installation options
Front and side access housings and frames are available, Type 8, Type L, and FC Housings.
Comment
Fire rating: UL 900
Filter Class ASHRAE
MERV 9

Hospitals & Healthcare: St. James Hospital Dublin

Case Study: St James Hospital Prevents Aspergillus. Healthcare facilities must maintain the highest levels of cleanliness to promote health and healing. Camfil provides air cleaners for these environments. St. James Hospitaal in Dublin used Camfil for Aspergillus prevention.

Case Studies

Food & Beverage: World's Leading Beverage Company

Case Study: Clean Air For Leading Beverage Manufacturer. Air is the only ingredient involved in every aspect of food and beverage manufacturing. Air comes into contact with products from storage of goods all way to packaging. How can we help to keep your food processes safe?

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies

UNIVERSITY SEES PROOF OF 24% LOWER ANNUAL ENERGY COSTS USING CAMFIL FILTER VS COMPETING FILTER

Case Study: Energy Savings At Western United States University. A Life Cycle Costing (LCC) analysis proved the Camfil Durafil filter operated at a 24% lower energy cost per year than the Viledon T-60. The Camfil product would save the customer $14 per filter per year versus the alternative.

Case Studies

Call Auckland Office
+64 9 636 0663
Call Cambridge Office
+64 7 827 4142
Find a contact