30/30 ®

  • Water resistant cardboard frame.
  • Robust construction
  • Bonded cross members to maintain pleat spacing
  • Fully supported media bonded onto a wire support grid
  • Radial pleat design for full media utilization
  • Replaceable filter media
  • ICON7 iso16890.ai
  • ICON42 UL logo
  • ICON23 Eurovent_no_abc
Item Type ISO/PM rating Filter Class EN779 Filter Class ASHRAE Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa) Energy (kWh/year) Energy Class (Eurovent)
30/30 24x24x1 ePM10 50% G4 MERV 8 594 594 22 2380 60 >1100 E
30/30 24x20x1 ePM10 50% G4 MERV 8 495 594 22 1980 60 E
30/30 20x20x1 ePM10 50% G4 MERV 8 495 495 22 1650 60 E
30/30 25x20x1 ePM10 50% G4 MERV 8 495 622 22 2065 60 E
30/30 20x16x1 ePM10 50% G4 MERV 8 394 495 22 1326 60 E
30/30 25x16x1 ePM10 50% G4 MERV 8 394 622 22 1650 60 E
30/30 24x12x1 ePM10 50% G4 MERV 8 292 594 22 1190 60 E
30/30 24x24x2 ePM10 50% G4 MERV 8 594 594 44 3400 70 >1100 E
30/30 20x20x2 ePM10 50% G4 MERV 8 495 495 44 2363 70 E
30/30 25x20x2 ePM10 50% G4 MERV 8 495 622 44 2958 70 E
30/30 24x20x2 ePM10 50% G4 MERV 8 495 594 44 2839 70 E
30/30 24x18x2 ePM10 50% G4 MERV 8 444 594 44 2550 70 E
30/30 25x16x2 ePM10 50% G4 MERV 8 394 622 44 2363 70 E
30/30 20x16x2 ePM10 50% G4 MERV 8 394 495 44 1870 70 E
30/30 24x16x2 ePM10 50% G4 MERV 8 394 594 44 2270 70 E
30/30 20x14x2 ePM10 50% G4 MERV 8 343 495 44 1658 70 E
30/30 24x12x2 ePM10 50% G4 MERV 8 289 594 44 1700 70 E
30/30 25x25x4 ePM10 50% G4 MERV 8 619 619 95 3689 65 D
30/30 24x24x4 ePM10 50% G4 MERV 8 594 594 95 3400 65 1098 D
30/30 25x20x4 ePM10 50% G4 MERV 8 492 619 95 2958 65 D
30/30 24x20x4 ePM10 50% G4 MERV 8 492 594 95 2839 65 D
30/30 20x20x4 ePM10 50% G4 MERV 8 492 492 95 2363 65 D
30/30 25x16x4 ePM10 50% G4 MERV 8 390 619 95 2363 65 D
30/30 20x16x4 ePM10 50% G4 MERV 8 390 492 95 1870 65 D
30/30 24x12x4 ePM10 50% G4 MERV 8 289 594 95 1700 65 D

Specifications

Application
Prevention of dust and dirt build up on heating/cooling coils within ventilation systems
Filter Frame
Cardboard
Media
Synthetic
Max temperature (°C)
70ÂșC maximum in continuous service
Recommended final pressure drop
250 Pa
Installation options
Holding frames: Front and side access housings and frames are available, Type 8 and FC Housings
Comment
Fire rating: UL 900
Filter Class ASHRAE
MERV 8

Articles related to 30/30

Camfil's clean air solutions at the Swedish Pavilion - EXPO 2020 Dubai

Camfil is an official sponsor of the Swedish pavilion by providing advanced clean air solutions that ensure better indoor air quality for visitors. EXPO 2020 in Dubai has started on October 1st, 2021 and will conclude on March 31st, 2022.

Take a breath Innovation Technology and Research Sustainability Education and Experience Air quality

Molecular filtration removes VOLATILE ORGANIC COMPOUNDS from the printing process exhaust in Thailand

S.Silpa Co., Ltd., Thailand faced constant odor nuisance and high VOC levels in their factory. This is due to the usage of various chemicals in the printing process that generate volatile organic compounds (VOCs) when exposed to heat, such as thinner solutions, alcohols, inks, cleaning solvents, vinyl sheets.

Case Studies Manufacturing and Machinery Air quality

Air Quality recommendations for hotels

Air quality has always been an important factor for hotels, whether it has been removing odours from kitchen extracts to ensuring a clean environment by reducing particulate levels.

Commercial and Public buildings Air cleaners and air purifiers Virus Contamination Control Air quality

Odour Exasperation - Here is what you can do in your restaurant to eliminate odour nuisance & neutralize the air

Restaurants have odours coming from a variety of sources and they all have one thing in common, they spread 'air pollution'. Odours are one of the leading causes of air pollution at restaurants or food courts and the odour profile from a kitchen depends on various factors.

Commercial and Public buildings Food and beverage Air quality

Dairy Processing Facility USA

Case Study: Dual 9 air filter. Higher performance, extended life (3-4 times longer), lower total cost and increased containment collection.

Case Studies Food and beverage

Grocery Store Case Study

Premium air filters help global grocer significantly improve air quality and reduce maintenance costs, waste and storage

Case Studies

Global Leader In Beverage Industry Cuts Annual Filter Use By More Than 80 Percent

Case Study: Bottled Water Producer Reduces Labour And Waste. One of the largest global food companies and a global leader in the bottled water industry, read about how this company turned to Camfil to help meet its strong commitment to health, hydration and the environment in particular.

Case Studies

Camfil Serves Up Savings in Energy, Filter Costs, and Labour

Case Study: Filter Savings At Frozen Food Manufacturer. Three air handling units supplied air to critical processing areas in one of the USA's largest frozen food manufacturing facilities. The pre and final filter combination saved the plant over $33,000 per year.

Case Studies

Call Auckland Office
+64 9 636 0663
Call Cambridge Office
+64 7 827 4142
Find a contact