CamGT 4V-300

  • Patented vertical pleat with open hot melt ensures water drainage
  • High filtration efficiency (up to H13)
  • Hydrophobic media
  • Low air resistance also in wet conditions
  • Solid HEPA frame eliminates air bypass
  • Resistant to turbulence and extreme pressure drop
  • Meets the industry’s most stringent requirements
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
Item Type ISO 16890 Filter Class EN779 Filter Class EN1822 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
Std ePM1 75% F7 592 592 292 4250 135
XL ePM1 75% F7 592 592 292 4250 125
Std ePM1 80% F8 592 592 292 4250 145
XL ePM1 80% F8 592 592 292 4250 135
Std ePM1 85% F9 592 592 292 4250 170
XL ePM1 85% F9 592 592 292 4250 160
Std E10 592 592 292 4250 210
Half size ePM1 75% F7 592 287 292 1700 135
Half size ePM1 85% F9 592 287 292 1700 170
Half size E10 592 287 292 1700 210
Std E11 592 592 292 4250 230
Std E12 592 592 292 4250 310
Std H13 592 592 292 3400 330
 Pressure drop calculation tool is available

Calculate pressure drop

Choose a full-size filter module in the table above to calculate the pressure drop.
Full-size filter modules are typically 592x592mm for bag/panel filters and 610x610mm for HEPA filters.

Specifications

Application
All installations where safety/reliability is important. All installations with high humidity/heavy rain
Frame
Plastic moulded
Media
Glass fiber
Max temperature °C
70°C
Relative Humidity
100%
Recommended final pressure drop
600 Pa
Separator
Hot-melt
Gasket
Polyurethane, endless foamed
Grille, Downstream
Support grid for filtermedia
Sealant
Polyurethane
Max Airflow
1,3 x nominal flow
Comment
Fire rating: Available according to DIN4102 class b2 rating on request
Burst strength: > 6250 Pa continuous wet/soaked
Reverse flow version: With support grid available on request
Additional information: Also available in 1/2 and 3/4 size on request.

Related Products

Articles related to CamGT

Image-Dalkia-Hero-ENG

Dalkia Power Generation

Case Study: Dalkia, a leader in the French gas turbine market, launched a national comparative test to increase power production by improving air filtration efficiency.

Case Studies Manufacturing and Machinery
Image-Gulf-of-Thailand-Hero-ENG.jpg

Gulf of Thailand Oil and Gas

Case Study: One of the world's Oil & Gas majors had severe problems associated with the operation of their gas turbines. Frequent peaks in inlet air pressure and short filter replacement intervals led to high operational costs.

Case Studies Turbomachinery

Pacific Coast Energy Plant

Case Study: An energy plant on the pacific coast upgrades to the camgt 4v-300 air inlet filters after tests show its water and salt handling capabilities.

Case Studies Turbomachinery

LNG & Air Filtration

Case Study: Achieving high reliability and availability compression systems for LNG export sites.

Case Studies Turbomachinery

Plant upgrades to the camGT 3V-600 for a 6-year lifecycle & to prevent engine degradation

Case Study: Comparison Test indicates a potential of $937 000 USD savings over a six-year timeframe by upgrading to EPA.

Case Studies Turbomachinery

EGAT North Power Generation

Case Study: EGAT North shifted to Camfil Filters and saved $1.4M USD in Yearly Power Degradation.

Case Studies Turbomachinery

RETROFIT SOLUTION FOR OFFSHORE PLATFORM

Case Study: The units are exposed to harsh environmental conditions that lead to spikes in pressure drop (dP) and excessive engine degradation from fouling and corrosion. As a result, the customer was forced to schedule unwanted shutdowns for maintenance.

Case Studies

CamGT Filters Reduce Noise & Bring Additional Profits Due To Lower Pressure Drop

Case Study: Noise complaints from neighboring communities prompted the plants to evaluate a noise-reducing filtration system.

Case Studies Turbomachinery

Dalkia Upgrades To EPA Class

Case Study: Camfil Wins Dalkia Over Four Competitors. Dalkia designed 12 testing benches to compare four air filtration combinations on three sites in France with different operating environments. Four competitors were free to select their best combinations.

Case Studies Turbomachinery

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies Turbomachinery