Hi-Cap XLS

  • Rigid self-supporting pockets
  • Moulded, stabile and aerodynamic plastic header in one piece
  • High mechanical strength
  • ICON7 iso16890.ai
  • ICON31 Mount_bagfilters
Item Type ISO 16890 Filter Class EN779 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
HC XLS-66/520 Coarse 60% G4 592 592 520 3400 30
HC XLS-66/370 Coarse 60% G4 592 592 370 3400 35
HC XLS-56/370 Coarse 60% G4 490 592 370 2800 35
HC XLS-36/370 Coarse 60% G4 287 592 370 1700 35
HC XLS-63/370 Coarse 60% G4 592 287 370 1700 35
HC XLS-65/370 Coarse 60% G4 592 490 370 2700 35
HC XLS-56/520 Coarse 60% G4 490 592 520 2800 30
HC XLS-36/520 Coarse 60% G4 287 592 520 1700 30
HC XLS-63/520 Coarse 60% G4 592 287 520 1700 30
HC XLS-65/520 Coarse 60% G4 592 490 520 2700 30
 Pressure drop calculation tool is available

Calculate pressure drop

m3/h
= Pa
Too high air flow for this filter

Specifications

Application
Pre-filtration for removing the largest particles in an air conditioning system
Frame
Plastic moulded
Media
Synthetic
Max temperature °C
70ÂșC
Relative Humidity
100%
Max final pressure drop, EN 13053
Initial pressure drop + 50 Pa or initial pressure drop x3 (whichever is lower)
Dimension standard
Filter front dimensions according EN 15805
Installation options
Front and side access housings and frames are available
Max Airflow
1,25 x nominal flow

Articles related to Hi-Cap

Hospitals & Healthcare: St. James Hospital Dublin

Case Study: St James Hospital Prevents Aspergillus. Healthcare facilities must maintain the highest levels of cleanliness to promote health and healing. Camfil provides air cleaners for these environments. St. James Hospitaal in Dublin used Camfil for Aspergillus prevention.

Case Studies

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies

UNIVERSITY SEES PROOF OF 24% LOWER ANNUAL ENERGY COSTS USING CAMFIL FILTER VS COMPETING FILTER

Case Study: Energy Savings At Western United States University. A Life Cycle Costing (LCC) analysis proved the Camfil Durafil filter operated at a 24% lower energy cost per year than the Viledon T-60. The Camfil product would save the customer $14 per filter per year versus the alternative.

Case Studies

SCHOOL LEARNS THE BENEFIT OF FRESH AIR

Case Study: School Learns the Benefit of Clean Air. Camfil worked with a school to help improve the indoor air quality for students during the critical exam period. They provided the school with Camfil air purifiers for use in their gymnasium where students sit their exams.

Case Studies