CamGT 3V-600

  • Low air resistance (dP) for optimal economy
  • Ensures water drainage
  • High filtration efficiency
  • Low air resistance also in wet/ dry conditions
  • Solid HEPA frame eliminates air bypass
  • Resistant to high and extreme pressure drops
  • Suitable for all environment
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
Item Type ISO/PM rating Filter Class EN779 Filter Class EN1822 Filter Class ASHRAE Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
3V600 ePM1 80% F8 MERV 14 592 592 600 4250 100
3V600 ePM1 85% F9 MERV 15 592 592 600 4250 115
3V600 E10 MERV 16 592 592 600 4250 135
3V600 E11 592 592 600 4250 140
3V600 E12 592 592 600 4250 190
 Pressure drop calculation tool is available

Calculate pressure drop

m3/h
= Pa
Too high air flow for this filter

Specifications

Application
All installations where safety/reliability is crucial in combination with low air resistance
Frame
Plastic moulded
Media
Glass fiber
Max temperature °C
70°C
Relative Humidity
100%
Recommended final pressure drop
600 Pa
Separator
Hot-melt
Gasket
Polyurethane, endless foamed
Grille, Downstream
Support grid for filtermedia
Sealant
Polyurethane
Max Airflow
1,8 x nominal flow
Additional Information
ME%: Minimum efficiency conform EN779:2012
Valid for H13; .99.97% efficiency at 0,3μm (= American HEPA)
Comment
Burst strength: > 6250 Pa continuous wet/soaked.
Filter Class ASHRAE
MERV 16

Related Products

Articles related to CamGT

RETROFIT SOLUTION FOR OFFSHORE PLATFORM

Case Study: The units are exposed to harsh environmental conditions that lead to spikes in pressure drop (dP) and excessive engine degradation from fouling and corrosion. As a result, the customer was forced to schedule unwanted shutdowns for maintenance.

Case Studies

CamGT 4v300

Case Study: Noise complaints from neighboring communities prompted the plants to evaluate a noise-reducing filtration system.

Case Studies Turbomachinery

Dalkia Upgrades To EPA Class

Case Study: Camfil Wins Dalkia Over Four Competitors. Dalkia designed 12 testing benches to compare four air filtration combinations on three sites in France with different operating environments. Four competitors were free to select their best combinations.

Case Studies Turbomachinery

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies Turbomachinery

Call Auckland Office
+64 9 636 0663
Call Cambridge Office
+64 7 827 4142
Find a contact