Absolute™ VE XL, XXL

  • High air flow
  • Applicable up to 5000 m³/h air flow
  • Low pressure drop
  • Ergonomic handle
  • Optimize the air filtration in clean rooms
  • ICON9 en1822
Item Type Filter Class EN1822 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
VEXL 11 289x595x292-PR E11 289 595 292 1700 250
VEXL11-595x595x292-PR E11 595 595 292 4200 250
VEXL11-610x610x292-PR E11 610 610 292 4000 250
VEXXL11-305x610x292-PR E11 305 610 292 2000 250
VEXL13-610x610x292-PR-S H13 610 610 292 3400 250
VEXL13-289x595x292-PR-S H13 289 595 292 1300 250
VEXL13-305x610x292-PR-S H13 305 610 292 1700 250
VEXL13-595x595x292-PR-S H13 595 595 292 3200 250
VEXL14-505x610x292-PR-S H14 305 610 292 1500 250
VEXL14-610x610x292-PR-S H14 610 610 292 3000 250
VEXL305x610x292-PR-S H14 305 610 292 1700 250
VEXXL11-610x610x292-PR E11 610 610 292 5000 250
VEXXL13-610x610x292-PR-S H13 610 610 292 4000 250
VEXXL14-610x610x292-PR-S H14 610 610 292 3400 250

Specifications

Application
Efficiency final filtration in air conditioning systems, housings and diffusers
Frame
Galvanised steel
Media
Glass fiber
Max temperature °C
70ºC
Relative Humidity
100%
Recommended final pressure drop
2x Initial pressure drop
Separator
Hot Melt
Gasket
Polyurethane, endless foamed
Sealant
Polyurethane
Installation options
Front and side access filter frames, FC housings, terminal housings and safe change systems
Max. final pressure drop
600 Pa
Comment
Remarks: Special versions on request (e.g. stainless steel frame or high temperature version 120ºC)

Hospitals & Healthcare: St. James Hospital Dublin

Case Study: St James Hospital Prevents Aspergillus. Healthcare facilities must maintain the highest levels of cleanliness to promote health and healing. Camfil provides air cleaners for these environments. St. James Hospitaal in Dublin used Camfil for Aspergillus prevention.

Case Studies

Food & Beverage: World's Leading Beverage Company

Case Study: Clean Air For Leading Beverage Manufacturer. Air is the only ingredient involved in every aspect of food and beverage manufacturing. Air comes into contact with products from storage of goods all way to packaging. How can we help to keep your food processes safe?

UNIVERSITY SEES PROOF OF 24% LOWER ANNUAL ENERGY COSTS USING CAMFIL FILTER VS COMPETING FILTER

Case Study: Energy Savings At Western United States University. A Life Cycle Costing (LCC) analysis proved the Camfil Durafil filter operated at a 24% lower energy cost per year than the Viledon T-60. The Camfil product would save the customer $14 per filter per year versus the alternative.

Case Studies

Call Auckland Office
+64 9 636 0663
Call Cambridge Office
+64 7 827 4142
Find a contact