City-Flo

Premium bag filters with particulate and molecular media to remove solid and gaseous contaminants in one filter stage. It can be used in existing installations to remove moderate concentrations of most external and internal pollutants with ePM1 efficiencies according to ISO16890.

  • “2-in-1” filtration solution; particulate and molecular
  • Removal of solid and gaseous contaminants in one filter stage
  • Ideal for filtering moderate concentrations of most external and internal source pollutants
  • Can be used to upgrade existing installations
  • Robust metal header frame
  • Classified according to ISO 10121-3
  • ICON3 efficiency guarantee
  • ICON6 Molecular
  • ICON7 iso16890.ai
  • ICON31 Mount_bagfilters
  • ICON37 ISO10121
  • ICON45 HAZE FREE
Item Type ISO 16890 Filter Class EN779 ISO 10121 Ozone ISO 10121 NO₂ ISO 10121 SO₂ ISO 10121 Toluene Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
7/534 ePM1 60% F7 HD 85 LD 85 MD 55 MD 80 592 592 534 3400 140
7/534 ePM1 60% F7 HD 85 LD 85 MD 55 MD 80 490 592 534 2800 140
7/534 ePM1 60% F7 HD 85 LD 85 MD 55 MD 80 287 592 534 1700 140
 Pressure drop calculation tool is available

Specifications

Application
Particle and odour removal in Hospitals, Offices, Airports etc.
Filter Frame
Galvanised steel
Media
Glass fiber/Activated carbon
Max temperature (°C)
50°C
Relative Humidity
70%
Max final pressure drop, EN 13053
Initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is lower)
Dimension standard
Filter front dimensions according EN 15805
Installation options
Front and side access housings and frames are available
Max Airflow
1,25 x nominal flow

Related Products

Articles related to City-Flo

DEVENTER HOSPITAL IN THE NETHERLANDS REMOVES FUME AND PARTICLES DUE TO FOSSIL FUEL USING UNIQUE 2-IN-1 AIR FILTER

the technical service department at Deventer hospital received complaints several times a year about unwanted diesel odours in different parts of the hospital building. Headaches was one the key problem among the laboratory staff. In operating rooms, the problem was significant because the air is circulated directly from the exhaust vent onto the operating table.

Case Studies Life science and healthcare Air quality Commercial and Public buildings

Odour Exasperation - Here is what you can do in your restaurant to eliminate odour nuisance & neutralize the air

Restaurants have odours coming from a variety of sources and they all have one thing in common, they spread 'air pollution'. Odours are one of the leading causes of air pollution at restaurants or food courts and the odour profile from a kitchen depends on various factors.

Food and beverage Air quality Commercial and Public buildings