CamVane 100

  • Air velocities between 1,0 to 5,0 m/s
  • Low noise level
  • Very low pressure drop
  • Weather resistant material
  • Separation efficiency up to 100 % rain
  • Minimal risk of freezing
  • ICON24 magicad
  • ICON35 camvane_function

Specifications

Application
Intake grille which is a very efficient for rainprotection. It is used in all filter installations where the water, rain and moisture problems occur, such as in marine environments, coastal areas, the rivers and inland
Installation options
Mounting flange or fastening ears to customer specifications.
Additional Information
Specifications CamVane 185
Air velocity (m/s) - 1,0 - 5,0
Size WxH (mm) - Up to 2500 x 2500
Depth D (mm) - 100
Optional extras:
•Installation flanges on the front or rear of the CamVane
Order example:
•CamVane 100 (w x h) 600 x 600 mm
Weight (kg/m2) - Approx. 35
Efficiency of droplet separator - cc 25 mm: 20 μm at 3,0 m/s
Tested by VTT in Finland to EN 13030:2001.
Determining the sound power level, pressure and flow from an air intake acc. to ISO 5135 (SP Report P906282 rev).
Comment
Type: CamVane has specially-shaped aluminium profiles which generate turbulence in the airflow.
Frame: Aluminium EN-AW-5754
Profiles: Aluminium EN-AW-6060.
Air velocities: 1.0 - 5.0 m/s in the duct system
Size: Supplied with any dimensions up to 2500 x 2500 mm
Deep: Standard 100 mm
Drainage: Supplied with drain at the bottom.
Air velocity (m/s): 1,0 - 5,0
Size WxH (mm): Up to 2500 x 2500
Deep D (mm): 100

Hospitals & Healthcare: St. James Hospital Dublin

Case Study: St James Hospital Prevents Aspergillus. Healthcare facilities must maintain the highest levels of cleanliness to promote health and healing. Camfil provides air cleaners for these environments. St. James Hospitaal in Dublin used Camfil for Aspergillus prevention.

Case Studies

Food & Beverage: World's Leading Beverage Company

Case Study: Clean Air For Leading Beverage Manufacturer. Air is the only ingredient involved in every aspect of food and beverage manufacturing. Air comes into contact with products from storage of goods all way to packaging. How can we help to keep your food processes safe?

Case Studies

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Case Studies

UNIVERSITY SEES PROOF OF 24% LOWER ANNUAL ENERGY COSTS USING CAMFIL FILTER VS COMPETING FILTER

Case Study: Energy Savings At Western United States University. A Life Cycle Costing (LCC) analysis proved the Camfil Durafil filter operated at a 24% lower energy cost per year than the Viledon T-60. The Camfil product would save the customer $14 per filter per year versus the alternative.

Case Studies

Call Auckland Office
+64 9 636 0663
Call Cambridge Office
+64 7 827 4142
Find a contact