Absolute D-Pyro

  • High temperature HEPA filter
  • H14 under all temp. conditions (H13 also available)
  • Maximum continuous operating temperature 350ºC,
  • Patented construction
  • Leakfree and eff. proven even after 200 cycles
  • Very robust construction
  • ProSafe + REACH compliance
  • ICON9 en1822
  • ICON20 prosafe
Item Type Filter Class EN1822 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa) Weight (kg)
H14 305 610 150 540 310 8,0
H14 457 457 150 620 300 9,0
DHT14-762x457x150-0-SP H14 762 457 150 1080 290 15
H14 457 610 150 850 300 12,0
H14 610 610 150 1180 290 16,0
H14 762 610 150 1500 290 34,0
H14 305 610 292 900 310 13,0
H14 457 610 292 1420 290 19,5
H14 610 610 292 1960 290 26,0
H14 762 610 292 2480 290 44,0
H13 305 610 150 460 250 8,0
H13 457 457 150 510 250 9,0
H13 457 610 150 750 250 12,0
H13 610 610 150 990 250 16,0
H13 762 610 150 1260 250 34,0
H13 305 610 292 780 250 13,0
H13 457 610 292 1310 250 19,5
H13 610 610 292 1850 250 26,0
H13 762 610 292 2250 250 44,0

Specifications

Application
HEPA filter protection for clean processes at high temperature, especially for Life Science (depyrogenation tunnels, ovens)
Frame
Stainless steel
Media
Glass fiber
Separator
Stainless steel
Sealant
Inorganic polymer
Max. final pressure drop
700 Pa
Comment
Temperature: 350 °C with peaks up to 400 °C.
ISO 5 under all production steps. Please note installation and assembly instructions! Other editions on request (with gasket, or sizes)