Termikfil 2000

  • Meets FDA requirements
  • Maximum continuous operating temperature 350°C, efficiency 99,99% at 0,3 1,1m
  • Ceramic frame
  • Efficiency tested after precuring
  • Exclusive precuring process at 300°C carried out in the plant
  • ICON9 en1822
Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
457 457 84 675 250
305 305 84 300 250
305 610 84 600 250
610 610 84 1200 250
457 610 84 900 250
762 610 84 1500 250
915 610 84 1800 250

Specifications

Application
Protection of ultra-clean processes at high temperature, sterilisation tunnels in the pharmaceutical industry
Frame
Composite ceramic
Media
Glass fiber
Installation options
Mounting: A stainless steel adaptor frame can be supplied to reach the thickness of 150mm or 292mm
Comment
Efficiency 0.3µm : > 99.99% @ front velocity 0.9m/s
Local penetration max.: 10-4 maximum,(0.01% acc. FDA) after the 1st heating cycle on site following Camfil procedure
Note : since full running condition in customer equipment are not able to be fully described, Camfil is not able to guarantee further to the 1st heating cycle on site
NB: To reduce fume emission when starting up, TERMIKFIL undergoes a specific precuring cycle in the factory at 300ºC using an exclusive CAMFIL process