Hi-Flo ProSafe

Premium bag filters developed for areas that require the highest hygienic demands. These filters are recommended for critical areas such as food and beverage as well as for pharma applications. The Hi-Flo ProSafe range comes with compliance to EC1935:2004, ISO846 and VDI6022 in ePM classes according to ISO16890.

  • ProSafe certified for Food & Beverage, Life Science, or close-to-product applications
  • Chemically resistant to decontamination, inactivation, and cleaning agent
  • Microbial inert components acc. to ISO 846
  • Compliant with VDI 6022
  • Free of bisphenol-A, phthalate, and formaldehyde
  • Tested for food safety acc. to EC 1935:2004
  • Manufactured and packed in a controlled environment
  • Packaging suitable for cleanroom unpacking
  • Certification and test results available online
  • ICON3 efficiency guarantee
  • ICON7 iso16890.ai
  • ICON32 Aplus
  • ICON20 prosafe
  • ICON23 Eurovent_no_abc
  • ICON31 Mount_bagfilters
Item Type ISO 16890 Filter Class EN779 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa) Energy (kWh/year) Energy Class (Eurovent)
6/640 ePM2,5 50% M6 592 592 640 3400 55 748 A
6/640 ePM2,5 50% M6 490 592 640 2800 55 A
6/640 ePM2,5 50% M6 287 592 640 1700 55 A
6/640 ePM2,5 50% M6 592 490 640 2800 55 A
6/640 ePM2,5 50% M6 490 490 640 2330 55 A
6/640 ePM2,5 50% M6 592 287 640 1700 55 A
6/640 ePM2,5 50% M6 287 287 640 800 55 A
6/520 ePM2,5 50% M6 592 592 520 3400 60 929 B
6/520 ePM2,5 50% M6 490 592 520 2800 60 B
6/520 ePM2,5 50% M6 287 592 520 1700 60 B
6/520 ePM2,5 50% M6 592 490 520 2800 60 B
6/520 ePM2,5 50% M6 490 490 520 2330 60 B
6/520 ePM2,5 50% M6 592 287 520 1700 60 B
6/520 ePM2,5 50% M6 287 287 520 800 60 B
6/370 ePM2,5 50% M6 592 592 370 3400 70 1405 D
6/370 ePM2,5 50% M6 490 592 370 2800 70 D
6/370 ePM2,5 50% M6 287 592 370 1700 70 D
6/370 ePM2,5 50% M6 592 490 370 2800 70 D
6/370 ePM2,5 50% M6 490 490 370 2330 70 D
6/370 ePM2,5 50% M6 592 287 370 1700 70 D
6/370 ePM2,5 50% M6 287 287 370 800 70 D
7/640 ePM1 60% F7 592 592 640 3400 65 811 A+
7/640 ePM1 60% F7 490 592 640 2800 65 A+
7/640 ePM1 60% F7 287 592 640 1700 65 A+
7/640 ePM1 60% F7 592 490 640 2800 65 A+
7/640 ePM1 60% F7 490 490 640 2330 65 A+
7/640 ePM1 60% F7 592 287 640 1700 65 A+
7/640 ePM1 60% F7 287 287 640 800 65 A+
7/520 ePM1 60% F7 592 592 520 3400 75 943 A
7/520 ePM1 60% F7 490 592 520 2800 75 A
7/520 ePM1 60% F7 287 592 520 1700 75 A
7/520 ePM1 60% F7 592 490 520 2800 75 A
7/520 ePM1 60% F7 490 490 520 2330 75 A
7/520 ePM1 60% F7 592 287 520 1700 75 A
7/520 ePM1 60% F7 287 287 520 800 75 A
7/370 ePM1 60% F7 592 592 370 3400 100 1389 C
7/370 ePM1 60% F7 490 592 370 2800 100 C
7/370 ePM1 60% F7 287 592 370 1700 100 C
7/370 ePM1 60% F7 592 490 370 2800 100 C
7/370 ePM1 60% F7 490 490 370 2330 100 C
7/370 ePM1 60% F7 592 287 370 1700 100 C
7/370 ePM1 60% F7 287 287 370 800 100 C
0170/640 ePM1 70% 592 592 640 3400 95 1213 B
0170/640 ePM1 70% 490 592 640 2800 95 B
0170/640 ePM1 70% 287 592 640 1700 95 B
0170/640 ePM1 70% 592 490 640 2800 95 B
0170/640 ePM1 70% 490 490 640 2330 95 B
0170/640 ePM1 70% 592 287 640 1700 95 B
0170/640 ePM1 70% 287 287 640 800 95 B
0170/520 ePM1 70% 592 592 520 3400 115 1462 C
0170/520 ePM1 70% 490 592 520 2800 115 C
0170/520 ePM1 70% 287 592 520 1700 115 C
0170/520 ePM1 70% 592 490 520 2800 115 C
0170/520 ePM1 70% 490 490 520 2330 115 C
0170/520 ePM1 70% 592 287 520 1700 115 C
0170/520 ePM1 70% 287 287 520 800 115 C
9/640 ePM1 85% F9 592 592 640 3400 120 1474 C
9/640 ePM1 85% F9 490 592 640 2800 120 C
9/640 ePM1 85% F9 287 592 640 1700 120 C
9/640 ePM1 85% F9 592 490 640 2800 120 C
9/640 ePM1 85% F9 490 490 640 2330 120 C
9/640 ePM1 85% F9 592 287 640 1700 120 C
9/640 ePM1 85% F9 287 287 640 800 120 C
9/520 ePM1 85% F9 592 592 520 3400 165 2091 D
9/520 ePM1 85% F9 490 592 520 2800 165 D
9/520 ePM1 85% F9 287 592 520 1700 165 D
9/520 ePM1 85% F9 592 490 520 2800 165 D
9/520 ePM1 85% F9 490 490 520 2330 165 D
9/520 ePM1 85% F9 592 287 520 1700 165 D
9/520 ePM1 85% F9 287 287 520 800 165 D
 Pressure drop calculation tool is available

Calculate pressure drop

m3/h
= Pa
Too high air flow for this filter

Video

Specifications

Application
Air conditioning applications and as pre filters for clean rooms
Filter Frame
Plastic
Media
Glass fiber
Max temperature (°C)
70ºC
Relative Humidity
100%
Max final pressure drop, EN 13053
Initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is lower)
Dimension standard
Filter front dimensions according EN 15805
Installation options
Front and side access housings and frames are available.
Max Airflow
1,25 x nominal flow

Related Products

Articles related to Hi-Flo

Spara energi genom att se över dina filter i din fastighet

Select the right air filtration solution using Life Cycle Cost

The most important task for a filter is to reduce the amount of particles and pollutants in the ventilation air, but you can also reduce your energy costs if you look at which filters you have in the property by looking at the life cycle cost.

Sustainability Standard and regulations
Significant Reduction in Compressor Efficiency Degradation

CamGT EPA Filters Boost Gas Turbine Performance

Hi-Flo bag air filters and CamGT EPA air filter upgrade reduces compressor efficiency degradation by 80%, slashes 3 offline filter replacements, 7 online pre-filter replacements, and 3 offline water washes per year.

Case Studies Energy and Power Systems

North Power Generation HiFlo CamClose CamGT 4V300

Egat North, the largest energy producer in Thailand, upgraded to Hi-Flo and CamClose air intake pre-filters as well as CamGT final EPA air filters and lowered degradation by 70%, reduced water wash requirements, and saved approximately $1.24M USD per year.

Case Studies Energy and Power Systems

Norland Managed Services

Case Study: Indoor Air Quality Worth The Investment. This major bank is one of the world‘s largest financial institutions. Norland Managed services are the Facilities Management provider for their 600,000 square feet London office building, in central London.

Case Studies

Camfil Serves Up Savings in Energy, Filter Costs, and Labour

Case Study: Filter Savings At Frozen Food Manufacturer. Three air handling units supplied air to critical processing areas in one of the USA's largest frozen food manufacturing facilities. The pre and final filter combination saved the plant over $33,000 per year.

Case Studies

Dalkia Power Saves €172 000 / season with Camfil E10 EPA Filters

Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.

Case Studies Energy and Power Systems

Camfil ProSafe 

Some processes are more sensitive than others. If you work in the food and beverage or life science industries, you know how tough the demands on clean air are. To be sure you have the right filter, look for the ProSafe symbol.

Food and beverage Life science and healthcare Standard and regulations