Charge en profondeur synthétique Protection EPA
Article | ISO 29461 | Classe de filtration EN1822 | Débit (m3/h) | Diamètre 1 (mm) | Diamètre 2 (mm) | Longueur 1, Cylindrique (mm) | Longueur 2, Cylindrique (mm) | Perte de charge initiale (Pa) |
---|---|---|---|---|---|---|---|---|
CYL/CYL | T10 | E10 | 2500 | 445 | 324 | 660 | 660 | 140 |
Co/Cyl | T10 | E10 | 2500 | 445/324 | 324 | 660 | 660 | 200 |
Tenkay 34" | T10 | E10 | 1150 | 324 | 864 | 175 |
Huadian, a power generation company located in China, upgraded the air inlet filtration system to the GTC synthetic cartridge filters on GT PG9171E engines and improved pressure drop and availability despite the high humidity levels.
Études de cas TurbomachinesAfter three years of operation the CamPulse GTC F9 cartridge gas turbine air filters helped improve power output, decrease filter replacement frequency, and save over $400 000 as a result of lower pressure drop.
Études de cas Turbomachines