CamGT 4V-300

  • Patented vertical pleat with open hot melt ensures water drainage
  • High filtration efficiency (up to H13)
  • Hydrophobic media
  • Low air resistance also in wet conditions
  • Solid HEPA frame eliminates air bypass
  • Resistant to turbulence and extreme pressure drop
  • Meets the industry’s most stringent requirements
  • ICON34 gasket_01_00_10
  • ICON3 efficiency guarantee
  • ICON5
  • ICON7 iso16890.ai
  • ICON9 en1822
  • ICON15 LCC optimized
Item Type ISO/PM rating Filter Class EN779 Filter Class EN1822 Filter Class ASHRAE Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
4V300 M6 MERV 13 592 592 292 4250 105
4V-300 ePM1 75% F7 MERV 13 592 592 292 4250 135
4V300XL ePM1 75% F7 MERV 13 592 592 292 4250 125
4V300 ePM1 80% F8 MERV 14 592 592 292 4250 145
4V300XL ePM1 80% F8 MERV 14 592 592 292 4250 135
4V300 ePM1 85% F9 MERV 15 592 592 292 4250 170
4V300XL ePM1 85% F9 MERV 15 592 592 292 4250 160
4V300 E10 592 592 292 4250 210
4V300 E11 592 592 292 4250 230
4V300 E12 592 592 292 4250 310
 Pressure drop calculation tool is available

Calculate pressure drop

m3/h
= Pa
Too high air flow for this filter

Specifications

Application
All installations where safety/reliability is important
Frame
Plastic moulded
Media
Glass fiber
Max temperature (°C)
70°C
Relative Humidity
100%
Recommended final pressure drop
600 Pa
Filter Class ASHRAE
MERV 13
Separator
Hot-melt
Gasket
Polyurethane, endless foamed
Grille, Downstream
Support grid for filtermedia
Sealant
Polyurethane
Max Airflow
1,3 x nominal flow
Comment
Fire rating: Available according to DIN4102 class b2 rating on request
Burst strength: > 6250 Pa continuous wet/soaked
Reverse flow version: With support grid available on request
Additional information: Also available in 1/2 and 3/4 size on request.

Related Products

Articles related to CamGT

upgrade gt filtration to slash carbon emissions per mwh produced 

Upgrade GT filtration to cut carbon emissions per MWh produced

Energy and Power Systems

Camfil & Solar Turbines Collaborate On Designing A New SOLUTION 

Case Study: The units are exposed to harsh environmental conditions that lead to spikes in pressure drop (dP) and excessive engine degradation from fouling and corrosion. As a result, the customer was forced to schedule unwanted shutdowns for maintenance.

Energy and Power Systems Case Studies

CamGT Filters Reduce Noise & Bring Additional Profits Due To Lower Pressure Drop

Case Study: Noise complaints from neighboring communities prompted the plants to evaluate a noise-reducing filtration system.

Energy and Power Systems Case Studies

Dalkia Upgrades To EPA Class

Case Study: Camfil Wins Dalkia Over Four Competitors. Dalkia designed 12 testing benches to compare four air filtration combinations on three sites in France with different operating environments. Four competitors were free to select their best combinations.

Energy and Power Systems Case Studies

Tata Power Trombay Retrofit

Case Study: Retrofit Solutions For Tata Power Ltd. Based on the site survey, Camfil proposed replacement of the pulse filter system with a three-stage static/barrier filter system, considering the local environment filled with refineries and a thermal power plant nearby.

Energy and Power Systems Case Studies

Call Camfil Middle East Regional Office!
Find a contact