Protection of ultra-clean processes at high temperature, sterilisation tunnels in the pharmaceutical industry
Frame
Composite ceramic
Media
Glass fiber
Max Temp °C (Peak)
350ºC
Separator
Glassfiber
Gasket
Toroidal sealing ring
Grille, Downstream
Stainless steel
Grille, Upstream
Stainless steel
Sealant
Ceramic
Installation options
A stainless steel adaptor frame can be supplied to reach the thickness of 150mm or 292mm
Maximum PD (Pa)
350 Pa
Comment
Efficiency 0.3µm : > 99.99% @ front velocity 0.9m/s Local penetration max.: 10-4 maximum,(0.01% acc. FDA) after the 1st heating cycle on site following Camfil procedure Note : since full running condition in customer equipment are not able to be fully described, Camfil is not able to guarantee further to the 1st heating cycle on site NB: To reduce fume emission when starting up, TERMIKFIL undergoes a specific precuring cycle in the factory at 300ºC using an exclusive CAMFIL process