Megalam Fabsafe

HEPA (H14) and ULPA (U15, U16) filter panels with ultra low outgassing components especially made for turbulent and laminar airflow applications in microelectronic industry. Optimized with glass fiber media for low pressure drop and long life time.

  • Developed for microelectronic cleanrooms and equipment
  • Ideal for nanoparticle filtration (100 nm)
  • No organic outgassing from test aerosol
  • Ultra-low outgassing (dopant free) components
  • 100% filter scan tested according to ISO29463
  • Individual efficiency test reports
  • High dust holding capacity
  • Manufactured and packed in a controlled environment
  • ICON9 en1822
  • ICON12 Fabsafe
  • ICON42 UL logo
Item Type Filter Class EN1822 Width (mm) Height (mm) Depth (mm) Pressure drop (Pa)
Fabsafe MD H13 H13 1170 1170 66 110
Fabsafe MD H13 H13 1170 570 66 110
Fabsafe MD H14 H14 1170 1170 66 130
Fabsafe MD H14 H14 1170 570 66 130
Fabsafe MX H14 H14 1170 1170 90 90
Fabsafe MX H14 H14 1170 570 90 90
Fabsafe MG H14 H14 1170 1170 110 60
Fabsafe MG H14 H14 1170 570 110 60
Fabsafe MD U15 U15 1170 1170 66 140
Fabsafe MD U15 U15 1170 570 66 140
Fabsafe MX U15 U15 1170 1170 90 110
Fabsafe MX U15 U15 1170 570 90 110
Fabsafe MG U15 U15 1170 1170 110 80
Fabsafe MG U15 U15 1170 570 110 80
Fabsafe MX U16 U16 1170 1170 90 130
Fabsafe MX U16 U16 1170 570 90 130
Fabsafe MG U16 U16 1170 1170 110 90
Fabsafe MG U16 U16 1170 570 110 90

Specifications

Application
Microelectronic cleanrooms and equipment.Nanoparticle filtration
Filter Frame
Anodized aluminium
Media
Glass fiber
Max temperature (°C)
70ºC
Relative Humidity
100%
Recommended final pressure drop
MD: 500 Pa, MX: 600 pa, MG:800 Pa
Recommended final pressure drop
2x Initial pressure drop
Separator
Hot-melt
Gasket
EPDM
Grille, Downstream
Expanded metal painted
Grille, Upstream
Expanded metal painted
Sealant
Polyurethane
Max Airflow
Nominal flow rate (if not, efficiency drops)
Comment
Test: 100% individual scan test according to EN1822, IEST RP-CC007 or required standard
Test aerosol: PSL. Oil free
Fire rating: UL900 & FM4920
Remarks: Many frame options and dimensions are available on request

Articles related to Megalam

มลพิษทางอากาศส่งผลต่อความเสี่ยงในการก่อเกิดโรคมะเร็ง การป้องกันและลดความเสี่ยงมลพิษทางอากาศ - การกรองอากาศ

ไม่น่าแปลกใจเลยที่มลพิษทางอากาศมีส่วนเกี่ยวข้องกับมะเร็งปอด อย่างไรก็ตามสิ่งที่น่าตกใจก็คืออากาศที่ไม่ดีสามารถเพิ่มความเสี่ยงต่อการเสียชีวิตจากมะเร็งชนิดอื่น ๆ ได้เช่นมะเร็งเต้านมตับและมะเร็งตับอ่อน

Air cleaners and air purifiers Air quality

กลยุทธ์การเปลี่ยนตัวกรอง

Gas Turbine Application: คุณภาพของตัวกรองอากาศเข้าเป็นสิ่งจำเป็นสำหรับประสิทธิภาพของกังหันก๊าซ การปกป้องกังหันด้วยโซลูชันการกรองเฉพาะไซต์จะช่วยเพิ่มผลกำไร

Energy and Power Systems