Absolute CM

  • Luftflöden, upp till 2500 m³/h
  • Hög avskiljningsgrad
  • Flera valbara storlekar
  • Brännbar
  • ICON9 en1822
Typ Filterklass enligt EN1822 Bredd (mm) Höjd (mm) Djup (mm) Luftflöde (m3/h) Initialt tryckfall (Pa)
Absolute CMT13-PR H13 305 305 292 535 250
Absolute CMT13-PR H13 305 610 292 1155 250
Absolute CMT13-PR H13 610 610 292 2450 250
Absolute CMT13 PR-H H13 595 595 292 2255 250
Absolute CMT13 PR-H H13 289 595 292 1000 250
Absolute CMT13 PR-H H13 595 289 292 1000 250
Absolute CMT13 PR-H H13 289 289 292 450 250

Specifikationer

Applikation
Installation i kritiska miljöer, som skydd t.ex. i livsmedelsproduktion och läkemedelstillverkning
Ram
MDF
Media
Glasfiber
Max. temp. °C
70ºC
Relativ fuktighet
100%
Rekommenderat sluttryckfall
2x initialt tryckfall
Separator
Smältlim
Packning
Ändlös PU-packning
Tätning
Polyuretan
installationsalternativ
Filterskåp Camcube AC, AD, AS och CamBox
Max. tryckfall (Pa)
800 Pa
Kommentar
Notera: Inviduellt testade enligt EN 1822:2009, testprotokoll medlevereras
*Tryckfall: +- 15%

Articles related to Absolute™ C,D

Hospitals & Healthcare: St. James Hospital Dublin

Case Study: St James Hospital Prevents Aspergillus. Healthcare facilities must maintain the highest levels of cleanliness to promote health and healing. Camfil provides air cleaners for these environments. St. James Hospitaal in Dublin used Camfil for Aspergillus prevention.

Case Studies

Food & Beverage: World's Leading Beverage Company

Case Study: Clean Air For Leading Beverage Manufacturer. Air is the only ingredient involved in every aspect of food and beverage manufacturing. Air comes into contact with products from storage of goods all way to packaging. How can we help to keep your food processes safe?

Camtain® Contains Explosive Pharma Dust

Case Study: Camtain Contains Explosive Pharma Dust. A multinational pharmaceutical company needed a dust extraction system for their new tableting suite in Spain. The suite comprised of six rooms, each with its own tablet machine that created explosive dusts.

Case Studies

UNIVERSITY SEES PROOF OF 24% LOWER ANNUAL ENERGY COSTS USING CAMFIL FILTER VS COMPETING FILTER

Case Study: Energy Savings At Western United States University. A Life Cycle Costing (LCC) analysis proved the Camfil Durafil filter operated at a 24% lower energy cost per year than the Viledon T-60. The Camfil product would save the customer $14 per filter per year versus the alternative.

Case Studies

SCHOOL LEARNS THE BENEFIT OF FRESH AIR

Case Study: School Learns the Benefit of Clean Air. Camfil worked with a school to help improve the indoor air quality for students during the critical exam period. They provided the school with Camfil air purifiers for use in their gymnasium where students sit their exams.

Case Studies