Hi-Flo A, UF

The entry level range of glass fiber bag filters with a reduced amount of bags with steel frame. Thanks to the conical and tapered bag design, these filters come with the optimum balance between price and total cost of ownership. Available in all efficiencies according to ISO16890.

  • Low initial pressure drop
  • Flat pressure drop curve
  • Comprehensive range of standard sizes
  • Innovative pocket design for optimum air distribution
  • Conical pockets
  • Robust metal header frame
  • ICON3 efficiency guarantee
  • ICON7 iso16890.ai
  • ICON23 Eurovent_no_abc
  • ICON31 Mount_bagfilters
  • ICON53 EPD
Item Type ISO 16890 Filter Class EN779 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa) Energy (kWh/year) Energy Class (Eurovent)
A5 ePM10 60% M5 592 592 600 3400 40 645 B
B5 ePM10 60% M5 490 592 600 2800 40 B
C5 ePM10 60% M5 287 592 600 1700 40 B
C5-33 ePM10 60% M5 287 287 600 800 40 B
A5-63 ePM10 60% M5 592 287 600 1700 40 B
A5-65 ePM10 60% M5 592 490 600 2800 40 B
AL5 ePM10 60% M5 592 892 600 5000 40 B
BL5 ePM10 60% M5 490 892 600 4100 40 B
CL5 ePM10 60% M5 287 892 600 2500 40 B
UF5 ePM10 60% M5 592 592 600 3400 40 522 A
UG5 ePM10 60% M5 490 592 600 2800 40 A
UH5 ePM10 60% M5 287 592 600 1700 40 A
UH5-33 ePM10 60% M5 287 287 600 800 40 A
UF5-63 ePM10 60% M5 592 287 600 1700 40 A
UF5-65 ePM10 60% M5 592 490 600 2800 40 A
A5/520 ePM10 60% M5 592 592 520 3400 45 836 C
B5/520 ePM10 60% M5 490 592 520 2800 45 C
C5/520 ePM10 60% M5 287 592 520 1700 45 C
C5-33/520 ePM10 60% M5 287 287 520 800 45 C
A5-63/520 ePM10 60% M5 592 287 520 1700 45 C
A5-65/520 ePM10 60% M5 592 490 520 2800 45 C
A5/370 ePM10 60% M5 592 592 370 3400 55 >1200 E
B5/370 ePM10 60% M5 490 592 370 2800 55 E
C5/370 ePM10 60% M5 287 592 370 1700 55 E
C5-33/370 ePM10 60% M5 287 287 370 800 55 E
A5-36/370 ePM10 60% M5 592 287 370 1700 55 E
A5-65/370 ePM10 60% M5 592 490 370 2800 55 E
A6 ePM2,5 50% M6 592 592 600 3400 70 1189 C
B6 ePM2,5 50% M6 490 592 600 2800 70 C
C6 ePM2,5 50% M6 287 592 600 1700 70 C
C6-33 ePM2,5 50% M6 287 287 600 800 70 C
A6-63 ePM2,5 50% M6 592 287 600 1700 70 C
A6-65 ePM2,5 50% M6 592 490 600 2800 70 C
UF6 ePM2,5 50% M6 592 592 600 3400 60 872 B
UG6 ePM2,5 50% M6 490 592 600 2800 60 B
UH6 ePM2,5 50% M6 287 592 600 1700 60 B
UH6-33 ePM2,5 50% M6 287 287 600 800 55 B
UF6-63 ePM2,5 50% M6 592 287 600 1700 60 B
UF6-65 ePM2,5 50% M6 592 490 600 2800 60 B
UF6/520 ePM2,5 50% M6 592 592 520 3400 65 997 C
UG6/520 ePM2,5 50% M6 490 592 520 2800 65 C
UH6/520 ePM2,5 50% M6 287 592 520 1700 65 C
UH6-33/520 ePM2,5 50% M6 287 287 520 800 65 C
UF6-63/520 ePM2,5 50% M6 592 287 520 1700 65 C
UF6-65/520 ePM2,5 50% M6 592 490 520 2800 65 C
UF6/370 ePM2,5 50% M6 592 592 370 3400 80 1167 C
UG6/370 ePM2,5 50% M6 490 592 370 2800 80 C
UH6/370 ePM2,5 50% M6 287 592 370 1700 80 C
UH6-33/370 ePM2,5 50% M6 287 287 370 800 80 C
UF6-63/370 ePM2,5 50% M6 592 287 370 1700 80 C
UF6-65/370 ePM2,5 50% M6 592 490 370 2800 80 C
A7 ES ePM1 60% F7 592 592 600 3400 85 1217 C
B7 ES ePM1 60% F7 490 592 600 2800 85 C
C7 ES ePM1 60% F7 287 592 600 1700 85 C
C7-33 ES ePM1 60% F7 287 287 600 800 85 C
A7-63 ES ePM1 60% F7 592 287 600 1700 85 C
A7-65 ES ePM1 60% F7 592 490 600 2800 85 C
UF7 ES ePM1 60% F7 592 592 600 3400 75 946 A
UG7 ES ePM1 60% F7 490 592 600 2800 75 A
UH7 ES ePM1 60% F7 287 592 600 1700 75 A
UH7-33 ES ePM1 60% F7 287 287 600 800 75 A
UF7-63 ES ePM1 60% F7 592 287 600 1700 75 A
UF7-65 ES ePM1 60% F7 592 490 600 2800 75 A
UF7/520 ES ePM1 60% F7 592 592 520 3400 85 1093 B
UG7/520 ES ePM1 60% F7 490 592 520 2800 85 B
UH7/520 ES ePM1 60% F7 287 592 520 1700 85 B
UH7-33/520 ES ePM1 60% F7 287 287 520 800 85 B
UF7-63/520 ES ePM1 60% F7 592 287 520 1700 85 B
UF7-65/520 ES ePM1 60% F7 592 490 520 2800 85 B
UF7/370 ES ePM1 60% F7 592 592 370 3400 115 1670 D
UG7/370 ES ePM1 60% F7 490 592 370 2800 115 D
UH7/370 ES ePM1 60% F7 287 592 370 1700 115 D
UH7-33/370 ES ePM1 60% F7 287 287 370 800 115 D
UF7-63/370 ES ePM1 60% F7 592 287 370 1700 115 D
UF7-65/370 ES ePM1 60% F7 592 490 370 2800 115 D
A7 ePM1 70% F7 592 592 600 3400 130 1869 D
B7 ePM1 70% F7 490 592 600 2800 130 D
C7 ePM1 70% F7 287 592 600 1700 130 D
C7-33 ePM1 70% F7 287 287 600 800 130 D
A7-63 ePM1 70% F7 592 287 600 1700 130 D
A7-65 ePM1 70% F7 592 490 600 2800 130 D
UF7 ePM1 70% F7 592 592 600 3400 110 1314 C
UG7 ePM1 70% F7 490 592 600 2800 110 C
UH7 ePM1 70% F7 287 592 600 1700 110 C
UH7-33 ePM1 70% F7 287 287 600 800 110 C
UF7-63 ePM1 70% F7 592 287 600 1700 110 C
UF7-65 ePM1 70% F7 592 490 600 2800 110 C
UF7/520 ePM1 70% F7 592 592 520 3400 125 1711 D
UG7/520 ePM1 70% F7 490 592 520 2800 125 D
UH7/520 ePM1 70% F7 287 592 520 1700 125 D
UH7-33/520 ePM1 70% F7 287 287 520 800 125 D
UF7-63/520 ePM1 70% F7 592 287 520 1700 125 D
UF7-65/520 ePM1 70% F7 592 490 520 2800 125 D
UF7/370 ePM1 70% F7 592 592 370 3400 170 >2150 E
UG7/370 ePM1 70% F7 490 592 370 2800 170 E
UH7/370 ePM1 70% F7 287 592 370 1700 170 E
UH7-33/370 ePM1 70% F7 287 287 370 800 170 E
UF7-63/370 ePM1 70% F7 592 287 370 1700 170 E
UF7-65/370 ePM1 70% F7 592 490 370 2800 170 E
UF9 ePM1 85% F9 592 592 600 3400 160 1956 D
UG9 ePM1 85% F9 490 592 600 2800 160 D
UH9 ePM1 85% F9 287 592 600 1700 160 D
UH9-33 ePM1 85% F9 287 287 600 800 160 D
UF9-63 ePM1 85% F9 592 287 600 1700 160 D
UF9-65 ePM1 85% F9 592 490 600 2800 160 D
UF9/520 ePM1 85% F9 592 592 520 3400 175 2266 D
UG9/520 ePM1 85% F9 490 592 520 2800 175 D
UH9/520 ePM1 85% F9 287 592 520 1700 175 D
UH9-33/520 ePM1 85% F9 287 287 520 800 175 D
UF9-63/520 ePM1 85% F9 592 287 520 1700 175 D
UF9-65/520 ePM1 85% F9 592 490 520 2800 175 D
 Pressure drop calculation tool is available

Environmental Product Declaration (EPD)

View and download the certificate:

Hi-Flo A, UF ePM1 60% (Sweden)

Hi-Flo A, UF ePM1 60% (Slovakia)

Hi-Flo A, UF ePM10 60%, ePM1 70%, ePM1 85% (Slovakia)

Calculate pressure drop

m3/h
= Pa
Too high air flow for this filter

Video

Specifications

Application
Comfort air conditioning applications, pre filter applications
Filter Frame
Galvanised steel
Media
Glass fiber
Max temperature (°C)
70°C
Relative Humidity
100%
Max final pressure drop, EN 13053
Initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is lower)
Dimension standard
Filter front dimensions according EN 15805
Installation options
Front and side access housings and frames are available
Max Airflow
1,25 x nominal flow

Related Products

Articles related to Hi-Flo

Hi-Flo

Camfil launched the Hi-Flo bag filter range in 1969 and it has been our biggest success - Now we are introducing the Next Generation!

Innovation Technology and Research Commercial and Public buildings
Prosafe promobox

Camfil ProSafe 

Some processes are more sensitive than others. If you work in the food and beverage or life science industries, you know how tough the demands on clean air are. To be sure you have the right filter, look for the ProSafe symbol.

Food and beverage Life science and healthcare Standard and regulations

Odour Exasperation - Here is what you can do in your restaurant to eliminate odour nuisance & neutralize the air

Restaurants have odours coming from a variety of sources and they all have one thing in common, they spread 'air pollution'. Odours are one of the leading causes of air pollution at restaurants or food courts and the odour profile from a kitchen depends on various factors.

Commercial and Public buildings Food and beverage Air quality

9 questions about EPDs

Nine questions about Environmental Product Declarations (EPDs). Answered by Anders Sundvik, Vice President of R&D at Camfil.

Commercial and Public buildings Sustainability Standard and regulations Air quality

Poor air quality in schools is bad for children but easy to fix

What does poor air quality in schools do to a child’s health, well-being and ability to learn? Why are children more vulnerable to air pollution than adults? And how can you achieve, or advocate for, a healthy indoor air environment in the classroom?

Commercial and Public buildings Air cleaners and air purifiers Air quality

insufficient or non-existent laws stand in the way of reducing global air pollution

A recent United Nations study shows that many countries lack the necessary laws and regulations to combat air pollution. There are also significant differences in how countries monitor and measure air quality and present their data.

Commercial and Public buildings Standard and regulations Air quality

How usual items and actions affect the air and people

The air in our buildings is often 2-5 times more polluted, and in some cases, even a hundred times more polluted than the air outside. So, where do the pollutants in the indoor air come from and how do we mitigate their impact?

Commercial and Public buildings Air cleaners and air purifiers Air quality

ventilation is the art of helping your building breathe

Why is ventilation so important, how does it work and what factors ensure a healthy and productive indoor air environment in our buildings?

Commercial and Public buildings Sustainability Air quality

GLOBAL FAST FOOD RESTAURANT is using dynamic clean air solutions in china

Fast food stores are usually located in a crowded commercial area or building where there are problems such as polluted air, gases, and odours. The fresh air fan units in the ventilation system are often close to the pollution source, i.e., exhaust air of other shops in the building.

Case Studies Commercial and Public buildings

Where is the future of air filtration headed?

What are some of the challenges moving forward to achieve healthy and energy-efficient indoor air environments? And what are some of the new air filtration solutions that could potentially become a reality in the years to come?

Innovation Technology and Research Commercial and Public buildings Sustainability Air quality

Air Quality recommendations for hotels

Air quality has always been an important factor for hotels, whether it has been removing odours from kitchen extracts to ensuring a clean environment by reducing particulate levels.

Commercial and Public buildings Air cleaners and air purifiers Virus Contamination Control Air quality

SHOULD YOU OPEN THE WINDOW IN THE CITY TO LET FRESH AIR IN?

How do you best protect yourself from air pollution in a city environment? Is it safe to open a window to let the breeze in to cool your premises on a warm day? What about pollutants already present in your indoor air?

Commercial and Public buildings Air cleaners and air purifiers Air quality

major energy savings in the ventilation operation

Bornholm Hospital Denmark Uses Camfil Hi-Flo XLT and Experiences Major Energy Savings in Ventilation Operation

Camfil's bag filters constribute to Sky-Light's core focus of resources and energy consumption reduction

Camfil contacted Sky-Light A/S for energy optimization of Sky-Light's existing ventilation system. Using LCC calculations and a 23-week trial with monitoring of existing and new filters, Sky-Light achieved significant energy savings, according to their own calculations.

Case Studies Manufacturing and Machinery Sustainability Air quality

Camfil's clean air solutions at the Swedish Pavilion - EXPO 2020 Dubai

Camfil is an official sponsor of the Swedish pavilion by providing advanced clean air solutions that ensure better indoor air quality for visitors. EXPO 2020 in Dubai has started on October 1st, 2021 and will conclude on March 31st, 2022.

Take a breath Innovation Technology and Research Sustainability Education and Experience Air quality

Understand the Challenges in the indoor environment when the outdoor temperature changes

In cold winter months, our energy and heat needs increase as the temperature drops outside. The sudden temperature change can lead to a sharp increase in pollution levels in the outdoor air. In addition, the cold itself means that we spend even more time indoors, which brings us closer to each other. Many don't understand how it affects us and our indoor environment.

Commercial and Public buildings Air cleaners and air purifiers Air quality

Why do we need a deeper connection with the air we absolutely depend upon - indoor air quality

Camfil is in the vanguard of a growing international movement to reduce the negative health effects of polluted air. As a leader in clean air solutions, we actively inform and educate customers, decision-makers, and the general public about threatening air pollutants and the tangible benefits of effective air filtration and high indoor air quality.

Take a breath Commercial and Public buildings Air cleaners and air purifiers Virus Contamination Control Air quality

Select the right air filtration solution using Life Cycle Cost

The most important task for a filter is to reduce the amount of particles and pollutants in the ventilation air, but you can also reduce your energy costs if you look at which filters you have in the property by looking at the life cycle cost.

Sustainability Standard and regulations

CamGT EPA Filters Boost Gas Turbine Performance

Hi-Flo bag air filters and CamGT EPA air filter upgrade reduces compressor efficiency degradation by 80%, slashes 3 offline filter replacements, 7 online pre-filter replacements, and 3 offline water washes per year.

Case Studies Energy and Power Systems

Air quality recommendations for office spaces

Air quality in your office is important to protecting the health of your employees. Poor air quality can lead to an increased transmission of viruses between employees which can lead to lower productivity and increased sick days in your office

Commercial and Public buildings Air cleaners and air purifiers Virus Contamination Control Air quality

Air Quality recommendations for Meat processing FACILITY

Air quality in meat processing facilities is often the forgotten ingredient within their facility. Did you know that Meat processing factories are susceptible to the spread of airborne viruses and microbes? The temperature and humidity requirements along with the production processes lend to the survival of airborne microbes and viruses. This means that the airborne viruses can survive longer in the air than in other facilities.

Food and beverage Air cleaners and air purifiers Virus Contamination Control Air quality

EGAT North Power Generation Shifted to CamGT Filters and Saved $1.24M USD in Yearly Power Degradation

Egat North, the largest energy producer in Thailand, upgraded to Hi-Flo and CamClose air intake pre-filters as well as CamGT final EPA air filters and lowered degradation by 70%, reduced water wash requirements, and saved approximately $1.24M USD per year.

Case Studies Energy and Power Systems

Dalkia Power Saves €172 000 / season with Camfil E10 EPA Filters

Dalkia, a leader in the French gas turbine market, launched a national comparative test for various air intake filters, including Camfil's Hi-Flo pre-filters and CamGT EPA filters, to increase power production for their 10 GE LM6000 gas turbines.

Case Studies Energy and Power Systems

Norland Managed Services

Case Study: Indoor Air Quality Worth The Investment. This major bank is one of the world‘s largest financial institutions. Norland Managed services are the Facilities Management provider for their 600,000 square feet London office building, in central London.

Case Studies

Camfil Serves Up Savings in Energy, Filter Costs, and Labour

Case Study: Filter Savings At Frozen Food Manufacturer. Three air handling units supplied air to critical processing areas in one of the USA's largest frozen food manufacturing facilities. The pre and final filter combination saved the plant over $33,000 per year.

Case Studies