Opakfil GT/GTX

  • Low pressure drop
  • Large filter area
  • Easy mounting
  • 100% incinerable
  • Heavy duty construction
  • Aerodynamic construction
  • ICON3 efficiency guarantee
  • ICON8
  • ICON9 en1822
  • ICON23 Eurovent_no_abc
Model Name Filter Class EN779 Filter Class EN1822 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
GT F7 592 592 292 4250 110
GT F8 592 592 292 4250 114
GT F9 592 592 292 4250 153
GT E10 592 592 292 4250 230
GTX F7 592 592 315 4250 100
GTX F8 592 592 315 4250 130
GTX F9 592 592 315 4250 160
GTX E10 592 592 315 4250 230

Specifications

Application
For dry areas, where high humidity and hygroscopic dust are less occuring
Frame
Plastic moulded
Media
Glass fiber
Max temperature °C
70ÂșC
Recommended final pressure drop, EN 13053
450 Pa
Comment
Header frame: GT 25mm, GTX 20mm.