City-Flo XL

Premium bag filters with particulate and molecular media to remove solid and gaseous contaminants in one filter stage. It can be used in existing installations to remove low concentrations of most external and internal pollutants with ePM1 efficiencies according to ISO16890.

  • “2-in-1” filtration solution; particulate and molecular.
  • Removal of solid and gaseous contaminants in one filter stage
  • Ideal for filtering low concentrations of most external and internal source pollutants
  • Can be used to upgrade existing installations
  • Incinerable plastic header frame
  • Classified according to ISO 10121-3
  • ICON3 efficiency guarantee
  • ICON6 Molecular
  • ICON7 iso16890.ai
  • ICON31 Mount_bagfilters
  • ICON37 ISO10121
  • ICON45 HAZE FREE
Item Type ISO 16890 Filter Class EN779 ISO 10121 Ozone ISO 10121 NO₂ ISO 10121 SO₂ ISO 10121 Toluene Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
7/640 ePM1 60% F7 vLD 20 vLD 20 vLD 10 vLD 30 287 592 640 1700 85
7/640 ePM1 60% F7 vLD 20 vLD 20 vLD 10 vLD 30 592 592 640 3400 85
7/640 ePM1 60% F7 vLD 20 vLD 20 vLD 10 vLD 30 490 592 640 2800 85
7/520 ePM1 60% F7 vLD 20 vLD 20 vLD 10 vLD 30 592 592 520 3400 110
7/520 ePM1 60% F7 vLD 20 vLD 20 vLD 10 vLD 30 490 592 520 2800 110
7/520 ePM1 60% F7 vLD 20 vLD 20 vLD 10 vLD 30 287 592 520 1700 110
0185/640 ePM1 85% vLD 20 vLD 20 vLD 10 vLD 30 592 592 640 3400 150
0185/640 ePM1 85% vLD 20 vLD 20 vLD 10 vLD 30 490 592 640 2800 150
0185/640 ePM1 85% vLD 20 vLD 20 vLD 10 vLD 30 287 592 640 1700 150
0185/520 ePM1 85% vLD 20 vLD 20 vLD 10 vLD 30 592 592 520 3400 185
0185/520 ePM1 85% vLD 20 vLD 20 vLD 10 vLD 30 490 592 520 2800 185
0185/520 ePM1 85% vLD 20 vLD 20 vLD 10 vLD 30 287 592 520 1850 185
 Pressure drop calculation tool is available

Calculate pressure drop

Choose a full-size filter module in the table above to calculate the pressure drop.
Full-size filter modules are typically 592x592mm for bag/panel filters and 610x610mm for HEPA filters.

Specifications

Application
Particulate and molecular filter.
Filter Frame
Plastic moulded
Media
Glass fiber/Activated carbon
Max temperature (°C)
50ºC
Relative Humidity
70%
Max final pressure drop, EN 13053
Initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is lower)
Dimension standard
Filter front dimensions according EN 15805
Installation options
Front and side access housings and frames are available
Max Airflow
1,25 x nominal flow

Related Products

Articles related to City-Flo

DEVENTER HOSPITAL IN THE NETHERLANDS REMOVES FUME AND PARTICLES DUE TO FOSSIL FUEL USING UNIQUE 2-IN-1 AIR FILTER

the technical service department at Deventer hospital received complaints several times a year about unwanted diesel odours in different parts of the hospital building. Headaches was one the key problem among the laboratory staff. In operating rooms, the problem was significant because the air is circulated directly from the exhaust vent onto the operating table.

Case Studies Life science and healthcare Commercial and Public buildings Air quality

Odour Exasperation - Here is what you can do in your restaurant to eliminate odour nuisance & neutralize the air

Restaurants have odours coming from a variety of sources and they all have one thing in common, they spread 'air pollution'. Odours are one of the leading causes of air pollution at restaurants or food courts and the odour profile from a kitchen depends on various factors.

Food and beverage Commercial and Public buildings Air quality